YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Computing and Information Science in Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Computing and Information Science in Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Virtual Tissue Cutting With Haptic Feedback Using a Hybrid Actuator With DC Servomotor and Magnetorheological Brake

    Source: Journal of Computing and Information Science in Engineering:;2016:;volume( 016 ):;issue: 003::page 31002
    Author:
    Gonenc, Berk
    ,
    Gurocak, Hakan
    DOI: 10.1115/1.4033046
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Surgical training is an important and recent application where haptic interfaces are used to enhance the realism of virtual training simulators. Tissue cutting with surgical scissors is a common interaction mode in the simulations. The haptic interface needs to render a wide range of tissue properties and resistance forces accurately. In this research, we developed a hybrid haptic device made of a DC servomotor and a magnetorheological (MR) brake. The motor can provide fast dynamic response and compensate for inertia and friction effects of the device. But alone, it cannot supply high force levels and the sensation of stiff interaction with hard tissues such as tendons. On the other hand, the MRbrake can provide very stiff interaction forces yet cannot reflect fast dynamics that are encountered as the virtual scissors go through the tissue. The hybrid actuator developed in this work combines the two based on a control scheme that decomposes the actuator command signal into two branches considering each actuator's capabilities. It is implemented on a compact single degreeoffreedom (DOF) interface to simulate virtual tissue cutting with three different scissor types (Mayo, Metzenbaum, Iris) and four types of rat tissue (liver, muscle, skin, tendon). Results have shown close tracking of the desired force profile in all cases. Compared to just using a DC motor, the hybrid actuator provided a wider range of forces (up to 18 N) with fast response to render quick force variations without any instability for all simulated tissue and scissor types.
    • Download: (2.299Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Virtual Tissue Cutting With Haptic Feedback Using a Hybrid Actuator With DC Servomotor and Magnetorheological Brake

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/160610
    Collections
    • Journal of Computing and Information Science in Engineering

    Show full item record

    contributor authorGonenc, Berk
    contributor authorGurocak, Hakan
    date accessioned2017-05-09T01:26:49Z
    date available2017-05-09T01:26:49Z
    date issued2016
    identifier issn1530-9827
    identifier otherjcise_016_03_031002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160610
    description abstractSurgical training is an important and recent application where haptic interfaces are used to enhance the realism of virtual training simulators. Tissue cutting with surgical scissors is a common interaction mode in the simulations. The haptic interface needs to render a wide range of tissue properties and resistance forces accurately. In this research, we developed a hybrid haptic device made of a DC servomotor and a magnetorheological (MR) brake. The motor can provide fast dynamic response and compensate for inertia and friction effects of the device. But alone, it cannot supply high force levels and the sensation of stiff interaction with hard tissues such as tendons. On the other hand, the MRbrake can provide very stiff interaction forces yet cannot reflect fast dynamics that are encountered as the virtual scissors go through the tissue. The hybrid actuator developed in this work combines the two based on a control scheme that decomposes the actuator command signal into two branches considering each actuator's capabilities. It is implemented on a compact single degreeoffreedom (DOF) interface to simulate virtual tissue cutting with three different scissor types (Mayo, Metzenbaum, Iris) and four types of rat tissue (liver, muscle, skin, tendon). Results have shown close tracking of the desired force profile in all cases. Compared to just using a DC motor, the hybrid actuator provided a wider range of forces (up to 18 N) with fast response to render quick force variations without any instability for all simulated tissue and scissor types.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleVirtual Tissue Cutting With Haptic Feedback Using a Hybrid Actuator With DC Servomotor and Magnetorheological Brake
    typeJournal Paper
    journal volume16
    journal issue3
    journal titleJournal of Computing and Information Science in Engineering
    identifier doi10.1115/1.4033046
    journal fristpage31002
    journal lastpage31002
    identifier eissn1530-9827
    treeJournal of Computing and Information Science in Engineering:;2016:;volume( 016 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian