YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Multisegment Kinematics of the Spinal Column: Soft Tissue Artifacts Assessment

    Source: Journal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 007::page 71003
    Author:
    Mahallati, Sara
    ,
    Rouhani, Hossein
    ,
    Preuss, Richard
    ,
    Masani, Kei
    ,
    Popovic, Milos R.
    DOI: 10.1115/1.4033545
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A major challenge in the assessment of intersegmental spinal column angles during trunk motion is the inherent error in recording the movement of bony anatomical landmarks caused by soft tissue artifacts (STAs). This study aims to perform an uncertainty analysis and estimate the typical errors induced by STA into the intersegmental angles of a multisegment spinal column model during trunk bending in different directions by modeling the relative displacement between skinmounted markers and actual bony landmarks during trunk bending. First, we modeled the maximum displacement of markers relative to the bony landmarks with a multivariate Gaussian distribution. In order to estimate the distribution parameters, we measured these relative displacements on five subjects at maximum trunk bending posture. Then, in order to model the error depending on trunk bending angle, we assumed that the error grows linearly as a function of the bending angle. Second, we applied our error model to the trunk motion measurement of 11 subjects to estimate the corrected trajectories of the bony landmarks and investigate the errors induced into the intersegmental angles of a multisegment spinal column model. For this purpose, the trunk was modeled as a sevensegment rigidbody system described using 23 reflective markers placed on various bony landmarks of the spinal column. Eleven seated subjects performed trunk bending in five directions and the threedimensional (3D) intersegmental angles during trunk bending were calculated before and after error correction. While STA minimally affected the intersegmental angles in the sagittal plane (<16%), it considerably corrupted the intersegmental angles in the coronal (error ranged from 59% to 551%) and transverse (up to 161%) planes. Therefore, we recommend using the proposed error suppression technique for STAinduced error compensation as a tool to achieve more accurate spinal column kinematics measurements. Particularly, for intersegmental rotations in the coronal and transverse planes that have small range and are highly sensitive to measurement errors, the proposed technique makes the measurement more appropriate for use in clinical decisionmaking processes.
    • Download: (3.586Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Multisegment Kinematics of the Spinal Column: Soft Tissue Artifacts Assessment

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/160421
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorMahallati, Sara
    contributor authorRouhani, Hossein
    contributor authorPreuss, Richard
    contributor authorMasani, Kei
    contributor authorPopovic, Milos R.
    date accessioned2017-05-09T01:26:13Z
    date available2017-05-09T01:26:13Z
    date issued2016
    identifier issn0148-0731
    identifier otherbio_138_07_074501.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160421
    description abstractA major challenge in the assessment of intersegmental spinal column angles during trunk motion is the inherent error in recording the movement of bony anatomical landmarks caused by soft tissue artifacts (STAs). This study aims to perform an uncertainty analysis and estimate the typical errors induced by STA into the intersegmental angles of a multisegment spinal column model during trunk bending in different directions by modeling the relative displacement between skinmounted markers and actual bony landmarks during trunk bending. First, we modeled the maximum displacement of markers relative to the bony landmarks with a multivariate Gaussian distribution. In order to estimate the distribution parameters, we measured these relative displacements on five subjects at maximum trunk bending posture. Then, in order to model the error depending on trunk bending angle, we assumed that the error grows linearly as a function of the bending angle. Second, we applied our error model to the trunk motion measurement of 11 subjects to estimate the corrected trajectories of the bony landmarks and investigate the errors induced into the intersegmental angles of a multisegment spinal column model. For this purpose, the trunk was modeled as a sevensegment rigidbody system described using 23 reflective markers placed on various bony landmarks of the spinal column. Eleven seated subjects performed trunk bending in five directions and the threedimensional (3D) intersegmental angles during trunk bending were calculated before and after error correction. While STA minimally affected the intersegmental angles in the sagittal plane (<16%), it considerably corrupted the intersegmental angles in the coronal (error ranged from 59% to 551%) and transverse (up to 161%) planes. Therefore, we recommend using the proposed error suppression technique for STAinduced error compensation as a tool to achieve more accurate spinal column kinematics measurements. Particularly, for intersegmental rotations in the coronal and transverse planes that have small range and are highly sensitive to measurement errors, the proposed technique makes the measurement more appropriate for use in clinical decisionmaking processes.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleMultisegment Kinematics of the Spinal Column: Soft Tissue Artifacts Assessment
    typeJournal Paper
    journal volume138
    journal issue7
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4033545
    journal fristpage71003
    journal lastpage71003
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian