    A New Vascular Coupler Design for End to End Anastomosis: Fabrication and Proof of Concept Evaluation

    Source: Journal of Medical Devices:;2015:;volume( 009 ):;issue: 003::page 31002
    Author:
    Li, Huizhong
    ,
    Gehrke, Cody
    ,
    Gale, Bruce K.
    ,
    Sant, Himanshu
    ,
    Coats, Brittany
    ,
    Agarwal, Jay
    DOI: 10.1115/1.4029924
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Traditional handsuturing for vascular connection techniques is time consuming, expensive, and requires highly complex instruments and technical expertise. The aim of this study is to develop a new vascular coupler that can be used in endtoend anastomosis surgery in an easier and more efficient way for both arteries and veins. The vascular coupler has four rotatable wings and one translatable spike in each wing. Prototypes were manufactured using polytetrafluoroethylene (PTFE) and highdensity polyethylene (HDPE). A set of installation tools was designed to facilitate the anastomosis process. Proofofconcept testing with the vascular coupler using plastic tubes and porcine cadaver vessels showed that the coupler should work as designed. A simplified finite element (FE) model assisted in the evaluation of the tearing likelihood of human vessels during installation of the coupler. Results of tests on the coupler showed that the vascular coupler could be efficiently attached to blood vessels, did not leak after the anastomosis was performed, had sufficient joint strength, and had little impact on flow in the vessel. The entire anastomosis process can be completed in 3 min when using the vascular coupler to join porcine cadaver vessels.
    • Download: (1.752Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A New Vascular Coupler Design for End to End Anastomosis: Fabrication and Proof of Concept Evaluation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/159174
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorLi, Huizhong
    contributor authorGehrke, Cody
    contributor authorGale, Bruce K.
    contributor authorSant, Himanshu
    contributor authorCoats, Brittany
    contributor authorAgarwal, Jay
    date accessioned2017-05-09T01:21:54Z
    date available2017-05-09T01:21:54Z
    date issued2015
    identifier issn1932-6181
    identifier othermed_009_03_031002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/159174
    description abstractTraditional handsuturing for vascular connection techniques is time consuming, expensive, and requires highly complex instruments and technical expertise. The aim of this study is to develop a new vascular coupler that can be used in endtoend anastomosis surgery in an easier and more efficient way for both arteries and veins. The vascular coupler has four rotatable wings and one translatable spike in each wing. Prototypes were manufactured using polytetrafluoroethylene (PTFE) and highdensity polyethylene (HDPE). A set of installation tools was designed to facilitate the anastomosis process. Proofofconcept testing with the vascular coupler using plastic tubes and porcine cadaver vessels showed that the coupler should work as designed. A simplified finite element (FE) model assisted in the evaluation of the tearing likelihood of human vessels during installation of the coupler. Results of tests on the coupler showed that the vascular coupler could be efficiently attached to blood vessels, did not leak after the anastomosis was performed, had sufficient joint strength, and had little impact on flow in the vessel. The entire anastomosis process can be completed in 3 min when using the vascular coupler to join porcine cadaver vessels.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA New Vascular Coupler Design for End to End Anastomosis: Fabrication and Proof of Concept Evaluation
    typeJournal Paper
    journal volume9
    journal issue3
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4029924
    journal fristpage31002
    journal lastpage31002
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2015:;volume( 009 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian