Patient Specific Clavicle Reconstruction Using Digital Design and Additive ManufacturingSource: Journal of Mechanical Design:;2015:;volume( 137 ):;issue: 011::page 111418Author:Cronskأ¤r, Marie
,
Rأ¤nnar, Lars
,
Bأ¤ckstrأ¶m, Mikael
,
Nilsson, Kjell G
,
Samuelsson, Bأ¶rje
DOI: 10.1115/1.4030992Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: There is a trend toward operative treatment for certain types of clavicle fractures and these are usually treated with plate osteosynthesis. The subcutaneous location of the clavicle makes the plate fit important, but the clavicle has a complex shape, which varies greatly between individuals and hence standard plates often have a poor fit. Using computed tomography (CT) based design, the plate contour and screw positioning can be optimized to the actual case. A method for patientspecific plating using design based on CTdata, additive manufacturing (AM), and postprocessing was initially evaluated through three case studies, and the plate fit on the reduced fracture was tested during surgery (then replaced by commercial plates). In all three cases, the plates had an adequate fit on the reduced fracture. The time span from CT scan of the fracture to final implant was two days. An approach to achieve functional design and screwhole positioning was initiated. These initial trials of patientspecific clavicle plating using AM indicate the potential for a smoother plate with optimized screw positioning. Further, the approach facilitates the surgeon's work and operating time can be saved.
|
Collections
Show full item record
| contributor author | Cronskأ¤r, Marie | |
| contributor author | Rأ¤nnar, Lars | |
| contributor author | Bأ¤ckstrأ¶m, Mikael | |
| contributor author | Nilsson, Kjell G | |
| contributor author | Samuelsson, Bأ¶rje | |
| date accessioned | 2017-05-09T01:21:11Z | |
| date available | 2017-05-09T01:21:11Z | |
| date issued | 2015 | |
| identifier issn | 1050-0472 | |
| identifier other | md_137_11_111418.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/158919 | |
| description abstract | There is a trend toward operative treatment for certain types of clavicle fractures and these are usually treated with plate osteosynthesis. The subcutaneous location of the clavicle makes the plate fit important, but the clavicle has a complex shape, which varies greatly between individuals and hence standard plates often have a poor fit. Using computed tomography (CT) based design, the plate contour and screw positioning can be optimized to the actual case. A method for patientspecific plating using design based on CTdata, additive manufacturing (AM), and postprocessing was initially evaluated through three case studies, and the plate fit on the reduced fracture was tested during surgery (then replaced by commercial plates). In all three cases, the plates had an adequate fit on the reduced fracture. The time span from CT scan of the fracture to final implant was two days. An approach to achieve functional design and screwhole positioning was initiated. These initial trials of patientspecific clavicle plating using AM indicate the potential for a smoother plate with optimized screw positioning. Further, the approach facilitates the surgeon's work and operating time can be saved. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Patient Specific Clavicle Reconstruction Using Digital Design and Additive Manufacturing | |
| type | Journal Paper | |
| journal volume | 137 | |
| journal issue | 11 | |
| journal title | Journal of Mechanical Design | |
| identifier doi | 10.1115/1.4030992 | |
| journal fristpage | 111418 | |
| journal lastpage | 111418 | |
| identifier eissn | 1528-9001 | |
| tree | Journal of Mechanical Design:;2015:;volume( 137 ):;issue: 011 | |
| contenttype | Fulltext |