    Arc Interruptions in Tandem Pulsed Gas Metal Arc Welding

    Source: Journal of Manufacturing Science and Engineering:;2015:;volume( 137 ):;issue: 001::page 11004
    Author:
    Pablo Reis, Ruham
    ,
    Souza, Daniel
    ,
    Filho, Demostenes Ferreira
    DOI: 10.1115/1.4028681
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In addition to electromagnetic attraction between the arcs in Tandem Pulsed gas metal arc welding (GMAW), arc interruptions, mostly in the trailing arc at low mean current levels, may also occur, which is a phenomenon not widely discussed in the welding field. These arc interruptions must be avoided, since they also represent interruptions in metal fusion and deposition during the welding process, leading to lack of fusion/penetration and/or deposition flaws, adding cost for repairing operations. To improve the understanding on arc interruptions in Tandem Pulsed GMAW and how the current pulsing synchronism between the arcs relates to this phenomenon, this work proposes to evaluate the influence of parameters of adjacent arcs (Tandem Pulsed GMAW) and also of a single arc (GTAW—gas tungsten arc welding), but similarly subjected to magnetic deflection, on the occurrence of arc interruptions/extinctions. Highspeed filming was used to help understand the interruption/extinction mechanism. In the case of Tandem Pulsed GMAW, the pulses of current of the leading and trailing arcs need to be almostinphase to prevent interruptions in the trailing arc. The distance of 10 mm between the adjacent arcs helped reduce the incidence of trailing arc interruptions, yet keeping a sound weld visual quality. In the case of GTAW, the higher the electrical current flowing through the arcs and the shorter their lengths, the more they resist to the extinction. The trailing arc interruptions in Tandem Pulsed GMAW seem to be determined by the deflection and heat in this arc, and their prevention can be achieved by a balance between these two factors, which is reached by synchronized pulsing currents.
    • Download: (2.768Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Arc Interruptions in Tandem Pulsed Gas Metal Arc Welding

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/158616
    Collections
    • Journal of Manufacturing Science and Engineering

    Show full item record

    contributor authorPablo Reis, Ruham
    contributor authorSouza, Daniel
    contributor authorFilho, Demostenes Ferreira
    date accessioned2017-05-09T01:20:07Z
    date available2017-05-09T01:20:07Z
    date issued2015
    identifier issn1087-1357
    identifier othermanu_137_01_011004.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/158616
    description abstractIn addition to electromagnetic attraction between the arcs in Tandem Pulsed gas metal arc welding (GMAW), arc interruptions, mostly in the trailing arc at low mean current levels, may also occur, which is a phenomenon not widely discussed in the welding field. These arc interruptions must be avoided, since they also represent interruptions in metal fusion and deposition during the welding process, leading to lack of fusion/penetration and/or deposition flaws, adding cost for repairing operations. To improve the understanding on arc interruptions in Tandem Pulsed GMAW and how the current pulsing synchronism between the arcs relates to this phenomenon, this work proposes to evaluate the influence of parameters of adjacent arcs (Tandem Pulsed GMAW) and also of a single arc (GTAW—gas tungsten arc welding), but similarly subjected to magnetic deflection, on the occurrence of arc interruptions/extinctions. Highspeed filming was used to help understand the interruption/extinction mechanism. In the case of Tandem Pulsed GMAW, the pulses of current of the leading and trailing arcs need to be almostinphase to prevent interruptions in the trailing arc. The distance of 10 mm between the adjacent arcs helped reduce the incidence of trailing arc interruptions, yet keeping a sound weld visual quality. In the case of GTAW, the higher the electrical current flowing through the arcs and the shorter their lengths, the more they resist to the extinction. The trailing arc interruptions in Tandem Pulsed GMAW seem to be determined by the deflection and heat in this arc, and their prevention can be achieved by a balance between these two factors, which is reached by synchronized pulsing currents.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleArc Interruptions in Tandem Pulsed Gas Metal Arc Welding
    typeJournal Paper
    journal volume137
    journal issue1
    journal titleJournal of Manufacturing Science and Engineering
    identifier doi10.1115/1.4028681
    journal fristpage11004
    journal lastpage11004
    identifier eissn1528-8935
    treeJournal of Manufacturing Science and Engineering:;2015:;volume( 137 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian