    Gas Turbine Engine Behavioral Modeling

    Source: Journal of Engineering for Gas Turbines and Power:;2015:;volume( 137 ):;issue: 012::page 122606
    Author:
    Meyer, Richard T.
    ,
    DeCarlo, Raymond A.
    ,
    Pekarek, Steve
    ,
    Doktorcik, Chris
    DOI: 10.1115/1.4030838
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper develops and validates a power flow behavioral model of a gas turbine engine (GTE) composed of a gas generator and free power turbine. The behavioral model is suitable for supervisory level (optimal) controller development of the engine itself or of electrical power systems containing gasturbinegenerator pairs as might be found in a naval ship or terrestrial electric utility plant. First principles engine models do not lend themselves to the supervisory level control development because of their high granularity. For the behavioral model, “simpleâ€‌ mathematical expressions that describe the engine's internal power flows are derived from an understanding of the engine's internal thermodynamic and mechanical interactions. These simple mathematical expressions arise from the balance of energy flow across engine components, power flow being the time derivative of energy flow. The parameter fit of the model to a specific engine such as the GE LM2500 detailed in this work utilizes constants and empirical fits of power conversion efficiencies obtained using data collected from a highfidelity engine simulator such as the Gas Turbine Simulation Program (GSP). Transient response tests show that the twonorm normalized error between the detailed simulator model and behavioral model outputs to be 2.7% or less for a GE LM2500.
    • Download: (1.060Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Gas Turbine Engine Behavioral Modeling

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/158115
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorMeyer, Richard T.
    contributor authorDeCarlo, Raymond A.
    contributor authorPekarek, Steve
    contributor authorDoktorcik, Chris
    date accessioned2017-05-09T01:18:29Z
    date available2017-05-09T01:18:29Z
    date issued2015
    identifier issn1528-8919
    identifier othergtp_137_12_122606.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/158115
    description abstractThis paper develops and validates a power flow behavioral model of a gas turbine engine (GTE) composed of a gas generator and free power turbine. The behavioral model is suitable for supervisory level (optimal) controller development of the engine itself or of electrical power systems containing gasturbinegenerator pairs as might be found in a naval ship or terrestrial electric utility plant. First principles engine models do not lend themselves to the supervisory level control development because of their high granularity. For the behavioral model, “simpleâ€‌ mathematical expressions that describe the engine's internal power flows are derived from an understanding of the engine's internal thermodynamic and mechanical interactions. These simple mathematical expressions arise from the balance of energy flow across engine components, power flow being the time derivative of energy flow. The parameter fit of the model to a specific engine such as the GE LM2500 detailed in this work utilizes constants and empirical fits of power conversion efficiencies obtained using data collected from a highfidelity engine simulator such as the Gas Turbine Simulation Program (GSP). Transient response tests show that the twonorm normalized error between the detailed simulator model and behavioral model outputs to be 2.7% or less for a GE LM2500.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleGas Turbine Engine Behavioral Modeling
    typeJournal Paper
    journal volume137
    journal issue12
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4030838
    journal fristpage122606
    journal lastpage122606
    identifier eissn0742-4795
    treeJournal of Engineering for Gas Turbines and Power:;2015:;volume( 137 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian