    Comparative Study of Using R 410A, R 407C, R 22, and R 134a as Cooling Medium in the Condenser of a Steam Power Plant

    Source: Journal of Engineering for Gas Turbines and Power:;2015:;volume( 137 ):;issue: 002::page 22002
    Author:
    Yousef, Khaled
    ,
    Assefa, Abebayehu
    ,
    Hegazy, Ahmed
    ,
    Engeda, Abraham
    DOI: 10.1115/1.4028266
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A stepbystep technique has been implemented in the analytical study of heat transfer and pressure gradient characteristics of refrigerants R410A, R407C, R22, and R134a used as cooling media in the condenser of a steam power plant. Refrigerants are optimized to replace water/air as coolant in the condenser of a steam power plant. Refrigerants have much lower temperatures and much higher heat transfer rates than water or air. The thermal resistances that affect heat transfer characteristics and surface condenser performance are included. The effect of inlet refrigerant temperature and mass flow rate are reported for the four refrigerants. Calculations are performed at two inlet refrigerant temperatures −21 آ°C and −30 آ°C and mass flow rate ranging from 92.905 to 132.905 kg/s. The results revealed that the overall heat transfer coefficient, heat transfer rate, and condensation rate increased with refrigerant mass flow rate, with higher values at lower inlet refrigerant temperatures. For a given refrigerant mass flow rate and inlet temperature, the analytical study indicated that R410A has higher values of overall heat transfer coefficient, heat transfer rate and condensation rate than R407C, R22, and R314a, respectively. Moreover, it is found that R410A, at −30 آ°C and 132.905 kg/s, is superior in condensing all steam entering the condenser than the other refrigerants; this corresponds to higher exergy efficiency. The condenser pressure was observed to be slightly higher for R410A than the other refrigerants.
    • Download: (1.291Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Comparative Study of Using R 410A, R 407C, R 22, and R 134a as Cooling Medium in the Condenser of a Steam Power Plant

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/157863
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorYousef, Khaled
    contributor authorAssefa, Abebayehu
    contributor authorHegazy, Ahmed
    contributor authorEngeda, Abraham
    date accessioned2017-05-09T01:17:30Z
    date available2017-05-09T01:17:30Z
    date issued2015
    identifier issn1528-8919
    identifier othergtp_137_02_022002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/157863
    description abstractA stepbystep technique has been implemented in the analytical study of heat transfer and pressure gradient characteristics of refrigerants R410A, R407C, R22, and R134a used as cooling media in the condenser of a steam power plant. Refrigerants are optimized to replace water/air as coolant in the condenser of a steam power plant. Refrigerants have much lower temperatures and much higher heat transfer rates than water or air. The thermal resistances that affect heat transfer characteristics and surface condenser performance are included. The effect of inlet refrigerant temperature and mass flow rate are reported for the four refrigerants. Calculations are performed at two inlet refrigerant temperatures −21 آ°C and −30 آ°C and mass flow rate ranging from 92.905 to 132.905 kg/s. The results revealed that the overall heat transfer coefficient, heat transfer rate, and condensation rate increased with refrigerant mass flow rate, with higher values at lower inlet refrigerant temperatures. For a given refrigerant mass flow rate and inlet temperature, the analytical study indicated that R410A has higher values of overall heat transfer coefficient, heat transfer rate and condensation rate than R407C, R22, and R314a, respectively. Moreover, it is found that R410A, at −30 آ°C and 132.905 kg/s, is superior in condensing all steam entering the condenser than the other refrigerants; this corresponds to higher exergy efficiency. The condenser pressure was observed to be slightly higher for R410A than the other refrigerants.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComparative Study of Using R 410A, R 407C, R 22, and R 134a as Cooling Medium in the Condenser of a Steam Power Plant
    typeJournal Paper
    journal volume137
    journal issue2
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4028266
    journal fristpage22002
    journal lastpage22002
    identifier eissn0742-4795
    treeJournal of Engineering for Gas Turbines and Power:;2015:;volume( 137 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian