    Effect of a Slotted Shield on Thermal and Hydraulic Performance of a Heat Sink

    Source: Journal of Electronic Packaging:;2015:;volume( 137 ):;issue: 001::page 11004
    Author:
    Elsayed, Mohamed L.
    ,
    Mesalhy, Osama
    DOI: 10.1115/1.4027920
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The attachment of a shield to a heat sink enhances the thermal performance. But, forming slots in the shield increases thermal resistance. We found that increasing the slot width enhances the flow performance over the heat sink and this improvement continues as the number of slots increases, but the thermal performance, on the other hand, decreases. Slots work as a flow bypass and create jets to destroy eddies and vortices created by the shield. Therefore, pressure drop at Re = 55,000 for a slotted case is about 80% lower than a solid shield. For suitable thermal resistance and moderate pressure drop, the appropriate slotted shield will have 3–7 slots at different slot widths. These slots preserve the improvement of thermal resistance with a suitable pressure drop.
    • Download: (1.397Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Effect of a Slotted Shield on Thermal and Hydraulic Performance of a Heat Sink

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/157661
    Collections
    • Journal of Electronic Packaging

    Show full item record

    contributor authorElsayed, Mohamed L.
    contributor authorMesalhy, Osama
    date accessioned2017-05-09T01:16:53Z
    date available2017-05-09T01:16:53Z
    date issued2015
    identifier issn1528-9044
    identifier otherep_137_01_011004.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/157661
    description abstractThe attachment of a shield to a heat sink enhances the thermal performance. But, forming slots in the shield increases thermal resistance. We found that increasing the slot width enhances the flow performance over the heat sink and this improvement continues as the number of slots increases, but the thermal performance, on the other hand, decreases. Slots work as a flow bypass and create jets to destroy eddies and vortices created by the shield. Therefore, pressure drop at Re = 55,000 for a slotted case is about 80% lower than a solid shield. For suitable thermal resistance and moderate pressure drop, the appropriate slotted shield will have 3–7 slots at different slot widths. These slots preserve the improvement of thermal resistance with a suitable pressure drop.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEffect of a Slotted Shield on Thermal and Hydraulic Performance of a Heat Sink
    typeJournal Paper
    journal volume137
    journal issue1
    journal titleJournal of Electronic Packaging
    identifier doi10.1115/1.4027920
    journal fristpage11004
    journal lastpage11004
    identifier eissn1043-7398
    treeJournal of Electronic Packaging:;2015:;volume( 137 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian