    The Influence of the Aortic Root Geometry on Flow Characteristics of a Prosthetic Heart Valve

    Source: Journal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 005::page 51005
    Author:
    Barannyk, Oleksandr
    ,
    Oshkai, Peter
    DOI: 10.1115/1.4029747
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In this paper, performance of aortic heart valve prosthesis in different geometries of the aortic root is investigated experimentally. The objective of this investigation is to establish a set of parameters, which are associated with abnormal flow patterns due to the flow through a prosthetic heart valve implanted in the patients that had certain types of valve diseases prior to the valve replacement. Specific valve diseases were classified into two clinical categories and were correlated with the corresponding changes in aortic root geometry while keeping the aortic base diameter fixed. These categories correspond to aortic valve stenosis and aortic valve insufficiency. The control case that corresponds to the aortic root of a patient without valve disease was used as a reference. Experiments were performed at test conditions corresponding to 70 beats/min, 5.5 L/min target cardiac output, and a mean aortic pressure of 100 mmHg. By varying the aortic root geometry, while keeping the diameter of the orifice constant, it was possible to investigate corresponding changes in the levels of Reynolds shear stress and establish the possibility of platelet activation and, as a result of that, the formation of blood clots.
    • Download: (6.598Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      The Influence of the Aortic Root Geometry on Flow Characteristics of a Prosthetic Heart Valve

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/157111
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorBarannyk, Oleksandr
    contributor authorOshkai, Peter
    date accessioned2017-05-09T01:15:08Z
    date available2017-05-09T01:15:08Z
    date issued2015
    identifier issn0148-0731
    identifier otherbio_137_05_051005.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/157111
    description abstractIn this paper, performance of aortic heart valve prosthesis in different geometries of the aortic root is investigated experimentally. The objective of this investigation is to establish a set of parameters, which are associated with abnormal flow patterns due to the flow through a prosthetic heart valve implanted in the patients that had certain types of valve diseases prior to the valve replacement. Specific valve diseases were classified into two clinical categories and were correlated with the corresponding changes in aortic root geometry while keeping the aortic base diameter fixed. These categories correspond to aortic valve stenosis and aortic valve insufficiency. The control case that corresponds to the aortic root of a patient without valve disease was used as a reference. Experiments were performed at test conditions corresponding to 70 beats/min, 5.5 L/min target cardiac output, and a mean aortic pressure of 100 mmHg. By varying the aortic root geometry, while keeping the diameter of the orifice constant, it was possible to investigate corresponding changes in the levels of Reynolds shear stress and establish the possibility of platelet activation and, as a result of that, the formation of blood clots.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Influence of the Aortic Root Geometry on Flow Characteristics of a Prosthetic Heart Valve
    typeJournal Paper
    journal volume137
    journal issue5
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4029747
    journal fristpage51005
    journal lastpage51005
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian