    Attenuation of Gas Pulsation in the Valve Chamber of a Reciprocating Compressor Using the Helmholtz Resonator

    Source: Journal of Vibration and Acoustics:;2014:;volume( 136 ):;issue: 005::page 51002
    Author:
    Jia, Xiaohan
    ,
    Liu, Boxiang
    ,
    Feng, Jianmei
    ,
    Peng, Xueyuan
    DOI: 10.1115/1.4027790
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper presents testing and analysis results associated with a new control method based on the Helmholtz resonator to suppress the pressure pulsations in the valve chamber and cylinder nozzle of a reciprocating compressor. The characteristic response of the designed Helmholtz resonator was analyzed and its attenuation characteristics on the gas pulsation were investigated. A threedimensional acoustic model of the gas pulsation was established by means of the finite element method (FEM) for a compressor discharge piping system with and without the resonator. The gas column natural frequencies of the piping system and the pressure wave profiles were predicted using the presented model and validated by comparing the simulated results with the experimental data. The results showed that the pressure pulsating amplitude in the valve chamber was reduced by 40.4% when the resonator was installed. If the resonance frequency of the resonator shifted from the cylinder nozzle characteristic frequency by a range of آ±13%, the reduction in the pressure fluctuations within the valve chamber was about 24%. The best attenuation effectiveness on the valve chamber, a reduction of 47%, was obtained when two resonators were installed on the valve covers of both the head and crank ends. Two new frequencies of 40.4 Hz and 66.9 Hz appeared to replace the original cylinder nozzle characteristic frequency of 53.9 Hz with the Helmholtz resonator installation, and the corresponding resonance region was transferred from the valve chamber to the resonator.
    • Download: (2.030Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Attenuation of Gas Pulsation in the Valve Chamber of a Reciprocating Compressor Using the Helmholtz Resonator

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/156807
    Collections
    • Journal of Vibration and Acoustics

    Show full item record

    contributor authorJia, Xiaohan
    contributor authorLiu, Boxiang
    contributor authorFeng, Jianmei
    contributor authorPeng, Xueyuan
    date accessioned2017-05-09T01:14:14Z
    date available2017-05-09T01:14:14Z
    date issued2014
    identifier issn1048-9002
    identifier othervib_136_05_051002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/156807
    description abstractThis paper presents testing and analysis results associated with a new control method based on the Helmholtz resonator to suppress the pressure pulsations in the valve chamber and cylinder nozzle of a reciprocating compressor. The characteristic response of the designed Helmholtz resonator was analyzed and its attenuation characteristics on the gas pulsation were investigated. A threedimensional acoustic model of the gas pulsation was established by means of the finite element method (FEM) for a compressor discharge piping system with and without the resonator. The gas column natural frequencies of the piping system and the pressure wave profiles were predicted using the presented model and validated by comparing the simulated results with the experimental data. The results showed that the pressure pulsating amplitude in the valve chamber was reduced by 40.4% when the resonator was installed. If the resonance frequency of the resonator shifted from the cylinder nozzle characteristic frequency by a range of آ±13%, the reduction in the pressure fluctuations within the valve chamber was about 24%. The best attenuation effectiveness on the valve chamber, a reduction of 47%, was obtained when two resonators were installed on the valve covers of both the head and crank ends. Two new frequencies of 40.4 Hz and 66.9 Hz appeared to replace the original cylinder nozzle characteristic frequency of 53.9 Hz with the Helmholtz resonator installation, and the corresponding resonance region was transferred from the valve chamber to the resonator.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAttenuation of Gas Pulsation in the Valve Chamber of a Reciprocating Compressor Using the Helmholtz Resonator
    typeJournal Paper
    journal volume136
    journal issue5
    journal titleJournal of Vibration and Acoustics
    identifier doi10.1115/1.4027790
    journal fristpage51002
    journal lastpage51002
    identifier eissn1528-8927
    treeJournal of Vibration and Acoustics:;2014:;volume( 136 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian