YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Vibration and Acoustics
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Vibration and Acoustics
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Simulation of Micromechanical Measurement of Mass Accretion: Quantifying the Importance of Material Selection and Geometry on Performance

    Source: Journal of Vibration and Acoustics:;2014:;volume( 136 ):;issue: 002::page 21003
    Author:
    Martin, Michael James
    DOI: 10.1115/1.4025842
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Microand nanomechanical resonators operating in liquid have been used to measure the change in the mass of either cells or functionalized surfaces attached to the resonator. As the system accretes mass, the natural frequency of the system changes, which can be measured experimentally. The current work extends methods previously developed for simulation of an atomic force microscope operating in liquid to study this phenomenon. A silicon cantilever with a 10 micron width, an 800 nm thickness, and a length of 30 microns was selected as a baseline configuration. The change in resonant frequency as the system accretes mass was determined through simulation. The results show that the change in natural frequency as mass accretes on the resonator is predictable through simulation. The geometry and material of the cantilever were varied to optimize the system. The results show that shorter cantilevers yield large gains in system performance. The width does not have a large impact on the system performance. Selecting the optimal thickness requires balancing the increase in overall system mass with the improvement in frequency response as the structure becomes thicker. Because there is no limit to the maximum system stiffness, the optimal materials will be those with higher elastic moduli. Based on these criteria, the optimum resonator for mass accretion measurements will be significantly different than an optimized atomicforce microscopy (AFM) cantilever.
    • Download: (453.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Simulation of Micromechanical Measurement of Mass Accretion: Quantifying the Importance of Material Selection and Geometry on Performance

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/156716
    Collections
    • Journal of Vibration and Acoustics

    Show full item record

    contributor authorMartin, Michael James
    date accessioned2017-05-09T01:13:58Z
    date available2017-05-09T01:13:58Z
    date issued2014
    identifier issn1048-9002
    identifier othervib_136_02_021003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/156716
    description abstractMicroand nanomechanical resonators operating in liquid have been used to measure the change in the mass of either cells or functionalized surfaces attached to the resonator. As the system accretes mass, the natural frequency of the system changes, which can be measured experimentally. The current work extends methods previously developed for simulation of an atomic force microscope operating in liquid to study this phenomenon. A silicon cantilever with a 10 micron width, an 800 nm thickness, and a length of 30 microns was selected as a baseline configuration. The change in resonant frequency as the system accretes mass was determined through simulation. The results show that the change in natural frequency as mass accretes on the resonator is predictable through simulation. The geometry and material of the cantilever were varied to optimize the system. The results show that shorter cantilevers yield large gains in system performance. The width does not have a large impact on the system performance. Selecting the optimal thickness requires balancing the increase in overall system mass with the improvement in frequency response as the structure becomes thicker. Because there is no limit to the maximum system stiffness, the optimal materials will be those with higher elastic moduli. Based on these criteria, the optimum resonator for mass accretion measurements will be significantly different than an optimized atomicforce microscopy (AFM) cantilever.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSimulation of Micromechanical Measurement of Mass Accretion: Quantifying the Importance of Material Selection and Geometry on Performance
    typeJournal Paper
    journal volume136
    journal issue2
    journal titleJournal of Vibration and Acoustics
    identifier doi10.1115/1.4025842
    journal fristpage21003
    journal lastpage21003
    identifier eissn1528-8927
    treeJournal of Vibration and Acoustics:;2014:;volume( 136 ):;issue: 002
    contenttypeFulltext