Design Considerations of Unglazed Transpired Collectors: Energetic and Exergetic StudiesSource: Journal of Solar Energy Engineering:;2014:;volume( 136 ):;issue: 003::page 31004DOI: 10.1115/1.4026251Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Unglazed transpired collector (UTC) is a kind of solar air heater is used for different applications such as air ventilation, preheating, and crop drying. Passing air through the perforated plate, which acts as an absorber, is the main mechanism of heat transfer and air preheating in UTCs. In order to design UTCs and determine the effective parameters, energy and exergy analyses are performed. A mathematical model which is solved using an iterative method by a computer code has been developed. In order to validate the present model, this solution is compared with numerical and experimental results available in the literature, where a good agreement is obtained. After verifying the model, the code has been used to study the influence of the effective parameters on the performance of the system. The results show that the exergetic analysis is very important to design.
|
Collections
Show full item record
| contributor author | Gholampour, M. | |
| contributor author | Ameri, M. | |
| date accessioned | 2017-05-09T01:12:26Z | |
| date available | 2017-05-09T01:12:26Z | |
| date issued | 2014 | |
| identifier issn | 0199-6231 | |
| identifier other | sol_136_03_031004.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/156286 | |
| description abstract | Unglazed transpired collector (UTC) is a kind of solar air heater is used for different applications such as air ventilation, preheating, and crop drying. Passing air through the perforated plate, which acts as an absorber, is the main mechanism of heat transfer and air preheating in UTCs. In order to design UTCs and determine the effective parameters, energy and exergy analyses are performed. A mathematical model which is solved using an iterative method by a computer code has been developed. In order to validate the present model, this solution is compared with numerical and experimental results available in the literature, where a good agreement is obtained. After verifying the model, the code has been used to study the influence of the effective parameters on the performance of the system. The results show that the exergetic analysis is very important to design. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Design Considerations of Unglazed Transpired Collectors: Energetic and Exergetic Studies | |
| type | Journal Paper | |
| journal volume | 136 | |
| journal issue | 3 | |
| journal title | Journal of Solar Energy Engineering | |
| identifier doi | 10.1115/1.4026251 | |
| journal fristpage | 31004 | |
| journal lastpage | 31004 | |
| identifier eissn | 1528-8986 | |
| tree | Journal of Solar Energy Engineering:;2014:;volume( 136 ):;issue: 003 | |
| contenttype | Fulltext |