    Condition Monitoring the Drive Train of a Direct Drive Permanent Magnet Wind Turbine Using Generator Electrical Signals

    Source: Journal of Solar Energy Engineering:;2014:;volume( 136 ):;issue: 002::page 21008
    Author:
    Yang, Wenxian
    DOI: 10.1115/1.4024983
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The benefit of wind turbine (WT) can be significantly improved through a wellorganized conditionbased maintenance strategy. However, such a target has not been fully achieved today. One of the major reasons is lack of an efficient WT condition monitoring system (CMS). The existing WT CMSs often involve high initial capital cost, with complex structure, suffer from inefficient management and show unsatisfactory hardware reliability. So, the operators still have desire for an economical, effective, and reliable CMS for their machines. The work reported in this paper is intended to meet such a demand. Because direct drive permanent magnet (PM) WTs are showing increased market share, but the existing WT CMSs are not designed to deal specifically with this new design, this paper reports on a CM technique dedicated to monitoring the drive train of direct drive WTs. Instead of taking the vibration analysis approach that is being popularly adopted by commercial WT CMSs, a novel CM strategy is researched in this paper by introducing generator electrical signals into WT CM and interpreting them by using a dedicated criterion named instantaneous variance (IV) and Teager–Huang transform (THT), i.e. the generator electrical signals will be evaluated first by using the IV, of which the fault detection capability can be further enhanced with the aid of empirical mode decomposition (EMD). Once an abnormality is detected, then detailed THT analysis of the signal will be conducted for further investigation. The technique has been verified experimentally on a specifically designed WT drive train test rig, on which a PM generator rotates at slow variable speed and is subjected to varying load like a real WT does. Considering the electric subassemblies and rotor blades of direct drive WTs are most vulnerable to damage in practice, rotor unbalance and generator winding faults were emulated on the test rig. Experimental results show that the proposed CM technique is effective in detecting both types of faults occurring in the drive train of direct drive PM WTs. In summary, the proposed CM technique can be identified by (i) the CM is accomplished through analyzing the generator electrical signals without resorting to any other information (e.g. vibroacoustic). Hence, the data acquisition work will be eased off; (ii) no more transducer other than current and voltage sensors are required. Thus, the cost of the CMS will be significantly reduced; (iii) attributed to the distinguished superiorities of THT to traditional spectral analyses in processing nonlinear signals, the proposed technique is more reliable in interpreting WT CM signals; and (iv) the CM criterion IV has a simple computational algorithm. It is therefore suited to both online and offline WT CM applications.
    • Download: (2.125Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Condition Monitoring the Drive Train of a Direct Drive Permanent Magnet Wind Turbine Using Generator Electrical Signals

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/156258
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorYang, Wenxian
    date accessioned2017-05-09T01:12:21Z
    date available2017-05-09T01:12:21Z
    date issued2014
    identifier issn0199-6231
    identifier othersol_136_02_021008.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/156258
    description abstractThe benefit of wind turbine (WT) can be significantly improved through a wellorganized conditionbased maintenance strategy. However, such a target has not been fully achieved today. One of the major reasons is lack of an efficient WT condition monitoring system (CMS). The existing WT CMSs often involve high initial capital cost, with complex structure, suffer from inefficient management and show unsatisfactory hardware reliability. So, the operators still have desire for an economical, effective, and reliable CMS for their machines. The work reported in this paper is intended to meet such a demand. Because direct drive permanent magnet (PM) WTs are showing increased market share, but the existing WT CMSs are not designed to deal specifically with this new design, this paper reports on a CM technique dedicated to monitoring the drive train of direct drive WTs. Instead of taking the vibration analysis approach that is being popularly adopted by commercial WT CMSs, a novel CM strategy is researched in this paper by introducing generator electrical signals into WT CM and interpreting them by using a dedicated criterion named instantaneous variance (IV) and Teager–Huang transform (THT), i.e. the generator electrical signals will be evaluated first by using the IV, of which the fault detection capability can be further enhanced with the aid of empirical mode decomposition (EMD). Once an abnormality is detected, then detailed THT analysis of the signal will be conducted for further investigation. The technique has been verified experimentally on a specifically designed WT drive train test rig, on which a PM generator rotates at slow variable speed and is subjected to varying load like a real WT does. Considering the electric subassemblies and rotor blades of direct drive WTs are most vulnerable to damage in practice, rotor unbalance and generator winding faults were emulated on the test rig. Experimental results show that the proposed CM technique is effective in detecting both types of faults occurring in the drive train of direct drive PM WTs. In summary, the proposed CM technique can be identified by (i) the CM is accomplished through analyzing the generator electrical signals without resorting to any other information (e.g. vibroacoustic). Hence, the data acquisition work will be eased off; (ii) no more transducer other than current and voltage sensors are required. Thus, the cost of the CMS will be significantly reduced; (iii) attributed to the distinguished superiorities of THT to traditional spectral analyses in processing nonlinear signals, the proposed technique is more reliable in interpreting WT CM signals; and (iv) the CM criterion IV has a simple computational algorithm. It is therefore suited to both online and offline WT CM applications.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCondition Monitoring the Drive Train of a Direct Drive Permanent Magnet Wind Turbine Using Generator Electrical Signals
    typeJournal Paper
    journal volume136
    journal issue2
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.4024983
    journal fristpage21008
    journal lastpage21008
    identifier eissn1528-8986
    treeJournal of Solar Energy Engineering:;2014:;volume( 136 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian