    An Experimental Powered Lower Limb Prosthesis Using Proportional Myoelectric Control

    Source: Journal of Medical Devices:;2014:;volume( 008 ):;issue: 002::page 24501
    Author:
    Huang, Stephanie
    ,
    Wensman, Jeffrey P.
    ,
    Ferris, Daniel P.
    DOI: 10.1115/1.4026633
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: One way to provide powered lower limb prostheses with greater adaptability to a wearer's intent is to use a neural signal to provide feedforward control of prosthesis mechanics. We designed and tested the feasibility of an experimental powered anklefoot prosthesis that uses pneumatic artificial muscles and proportional myoelectric control to vary ankle mechanics during walking. The force output of the artificial plantar flexor muscles was directly proportional to the subject's residual gastrocnemius muscle activity. The maximum force generated by a pair of artificial muscles fixed at nominal length was 3513 N. The maximum planter flexion torque that could be generated during walking was 176 Nm. The force bandwidth of the pneumatic artificial muscles was 2 Hz. The electromechanical delay was 33 ms, the time to peak tension was 48 ms, and the half relaxation time was 50 ms. We used two artificial muscles as dorsiflexors and two artificial muscles as plantar flexors. The prosthetic ankle had 25 deg of dorsiflexion and 35 deg of plantar flexion with the artificial muscles uninflated. The intent of the device was not to create a commercially viable prosthesis but to have a laboratory prototype to test principles of locomotor adaptation and biomechanics. We recruited one unilateral transtibial amputee to walk on a treadmill at 1.0 m/s while wearing the powered prosthesis. We recorded muscle activity within the subject's prescribed prosthetic socket using surface electrodes. The controller was active throughout the entire gait cycle and did not rely on detection of gait phases. The amputee subject quickly adapted to the powered prosthesis and walked with a functional gait. The subject generated peak ankle power at push off that was similar between amputated and prosthetic sides. Our results suggest that amputees can use their residual muscles for proportional myoelectric control to alter prosthetic mechanics during walking.
    • Download: (1.052Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      An Experimental Powered Lower Limb Prosthesis Using Proportional Myoelectric Control

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/155886
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorHuang, Stephanie
    contributor authorWensman, Jeffrey P.
    contributor authorFerris, Daniel P.
    date accessioned2017-05-09T01:11:14Z
    date available2017-05-09T01:11:14Z
    date issued2014
    identifier issn1932-6181
    identifier othermed_008_02_024501.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/155886
    description abstractOne way to provide powered lower limb prostheses with greater adaptability to a wearer's intent is to use a neural signal to provide feedforward control of prosthesis mechanics. We designed and tested the feasibility of an experimental powered anklefoot prosthesis that uses pneumatic artificial muscles and proportional myoelectric control to vary ankle mechanics during walking. The force output of the artificial plantar flexor muscles was directly proportional to the subject's residual gastrocnemius muscle activity. The maximum force generated by a pair of artificial muscles fixed at nominal length was 3513 N. The maximum planter flexion torque that could be generated during walking was 176 Nm. The force bandwidth of the pneumatic artificial muscles was 2 Hz. The electromechanical delay was 33 ms, the time to peak tension was 48 ms, and the half relaxation time was 50 ms. We used two artificial muscles as dorsiflexors and two artificial muscles as plantar flexors. The prosthetic ankle had 25 deg of dorsiflexion and 35 deg of plantar flexion with the artificial muscles uninflated. The intent of the device was not to create a commercially viable prosthesis but to have a laboratory prototype to test principles of locomotor adaptation and biomechanics. We recruited one unilateral transtibial amputee to walk on a treadmill at 1.0 m/s while wearing the powered prosthesis. We recorded muscle activity within the subject's prescribed prosthetic socket using surface electrodes. The controller was active throughout the entire gait cycle and did not rely on detection of gait phases. The amputee subject quickly adapted to the powered prosthesis and walked with a functional gait. The subject generated peak ankle power at push off that was similar between amputated and prosthetic sides. Our results suggest that amputees can use their residual muscles for proportional myoelectric control to alter prosthetic mechanics during walking.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAn Experimental Powered Lower Limb Prosthesis Using Proportional Myoelectric Control
    typeJournal Paper
    journal volume8
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4026633
    journal fristpage24501
    journal lastpage24501
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2014:;volume( 008 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian