    Thermal Conductivity and Interface Thermal Conductance in Composites of Titanium With Graphene Platelets

    Source: Journal of Heat Transfer:;2014:;volume( 136 ):;issue: 006::page 61301
    Author:
    Zheng, H.
    ,
    Jaganandham, K.
    DOI: 10.1115/1.4026488
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Composite films of graphene platelets (GPs) in titanium matrix were prepared on silicon (001) substrates by physical vapor deposition of titanium using magnetron sputtering and dispersion of graphene platelets. The graphene platelets were dispersed six times after each deposition of titanium film to form the composite film. Samples of titanium film and titanium film with a single layer of dispersed graphene platelets were also prepared by the same procedure. The distribution of the graphene platelets in the film was analyzed by scanning electron microscopy. Energy dispersive spectrometry was used to infer the absence of interstitial elements. The thermal conductivity of the composite and the interface thermal conductance between titanium and silicon or titanium and graphene platelets was determined by threeomega and transient thermo reflectance (TTR) techniques, respectively. The results indicate that the thermal conductivity of the composite is isotropic and improved to 40 Wm−1K−1 from 21 Wm−1 K−1 for Ti. The interface thermal conductance between titanium and silicon is found to be 200 MWm−2K−1 and that between titanium and graphene platelets in the Cdirection to be 22 MWm−2K−1. Modeling using acoustic and diffuse mismatch models was carried out to infer the magnitude of interface thermal conductance. The results indicate that the higher value of interface thermal conductance between graphene platelets in the ab plane and titanium matrix is responsible for the isotropic and improved thermal conductivity of the composite. Effective mean field analysis showed that the interface thermal conductance in the ab plane is high at 440 MWm−2K−1 when GPs consist of 8 atomic layers of graphene so that it is not a limitation to improve the thermal conductivity of the composites.
    • Download: (623.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Thermal Conductivity and Interface Thermal Conductance in Composites of Titanium With Graphene Platelets

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/155271
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorZheng, H.
    contributor authorJaganandham, K.
    date accessioned2017-05-09T01:09:26Z
    date available2017-05-09T01:09:26Z
    date issued2014
    identifier issn0022-1481
    identifier otherht_136_06_061301.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/155271
    description abstractComposite films of graphene platelets (GPs) in titanium matrix were prepared on silicon (001) substrates by physical vapor deposition of titanium using magnetron sputtering and dispersion of graphene platelets. The graphene platelets were dispersed six times after each deposition of titanium film to form the composite film. Samples of titanium film and titanium film with a single layer of dispersed graphene platelets were also prepared by the same procedure. The distribution of the graphene platelets in the film was analyzed by scanning electron microscopy. Energy dispersive spectrometry was used to infer the absence of interstitial elements. The thermal conductivity of the composite and the interface thermal conductance between titanium and silicon or titanium and graphene platelets was determined by threeomega and transient thermo reflectance (TTR) techniques, respectively. The results indicate that the thermal conductivity of the composite is isotropic and improved to 40 Wm−1K−1 from 21 Wm−1 K−1 for Ti. The interface thermal conductance between titanium and silicon is found to be 200 MWm−2K−1 and that between titanium and graphene platelets in the Cdirection to be 22 MWm−2K−1. Modeling using acoustic and diffuse mismatch models was carried out to infer the magnitude of interface thermal conductance. The results indicate that the higher value of interface thermal conductance between graphene platelets in the ab plane and titanium matrix is responsible for the isotropic and improved thermal conductivity of the composite. Effective mean field analysis showed that the interface thermal conductance in the ab plane is high at 440 MWm−2K−1 when GPs consist of 8 atomic layers of graphene so that it is not a limitation to improve the thermal conductivity of the composites.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThermal Conductivity and Interface Thermal Conductance in Composites of Titanium With Graphene Platelets
    typeJournal Paper
    journal volume136
    journal issue6
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4026488
    journal fristpage61301
    journal lastpage61301
    identifier eissn1528-8943
    treeJournal of Heat Transfer:;2014:;volume( 136 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian