    Application of Womersley Model to Reconstruct Pulsatile Flow From Doppler Ultrasound Measurements

    Source: Journal of Fluids Engineering:;2014:;volume( 136 ):;issue: 004::page 41102
    Author:
    Daidzic, Nihad E.
    DOI: 10.1115/1.4026481
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A Womersley modelbased assessment of pulsatile rigidtube flow is presented. Multigate Doppler ultrasound was used to measure axial velocities at many radial locations along a single interrogation beam going through the center of a stiff tube. However, a large impediment to Doppler ultrasound diagnostics and resolution close to the wall is considerable noise due to the presence of the wallfluid interface as well as many other effects, such as spectral broadening, coherent scattering, time resolution, and Doppler angle uncertainty. Thus, our confidence in measured signals is questionable, especially in the wall vicinity where the important oscillatory shear stresses occur. In order to alleviate known biases and shortcomings of the pulsed Doppler ultrasound measurements we have applied Womersley's laminar axisymmetric rigidtube approximation to reconstruct velocity profiles over the entire flow domain and specifically close to wall, enabling unambiguous determination of the shear stresses. We employ harmonic analysis of the measured velocity profiles at all or selected trusted tube radial locations over one or more periods. Each of estimated Fourier coefficients has a unique counterpart in the respective pressure gradient component. From ensembleaveraged crosssectional pressure gradient components we compute velocity profiles, volume flow rate, wall shear stress, and other flow parameters. Estimation of the pressure gradients from spatially resolved pulsed Doppler ultrasound velocity measurements is an added benefit of our reconstruction method. Multigate pulsed Doppler ultrasound scanners offer powerful capabilities to noninvasively and nonintrusively measure velocity profiles for hemodynamic and other fluid flow applications. This flow reconstruction method can also be tailored for use with other flow diagnostic modalities, such as magnetic resonance imaging (MRI) and a wide class of optical methods.
    • Download: (5.230Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Application of Womersley Model to Reconstruct Pulsatile Flow From Doppler Ultrasound Measurements

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/154975
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorDaidzic, Nihad E.
    date accessioned2017-05-09T01:08:30Z
    date available2017-05-09T01:08:30Z
    date issued2014
    identifier issn0098-2202
    identifier otherfe_136_04_041102.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/154975
    description abstractA Womersley modelbased assessment of pulsatile rigidtube flow is presented. Multigate Doppler ultrasound was used to measure axial velocities at many radial locations along a single interrogation beam going through the center of a stiff tube. However, a large impediment to Doppler ultrasound diagnostics and resolution close to the wall is considerable noise due to the presence of the wallfluid interface as well as many other effects, such as spectral broadening, coherent scattering, time resolution, and Doppler angle uncertainty. Thus, our confidence in measured signals is questionable, especially in the wall vicinity where the important oscillatory shear stresses occur. In order to alleviate known biases and shortcomings of the pulsed Doppler ultrasound measurements we have applied Womersley's laminar axisymmetric rigidtube approximation to reconstruct velocity profiles over the entire flow domain and specifically close to wall, enabling unambiguous determination of the shear stresses. We employ harmonic analysis of the measured velocity profiles at all or selected trusted tube radial locations over one or more periods. Each of estimated Fourier coefficients has a unique counterpart in the respective pressure gradient component. From ensembleaveraged crosssectional pressure gradient components we compute velocity profiles, volume flow rate, wall shear stress, and other flow parameters. Estimation of the pressure gradients from spatially resolved pulsed Doppler ultrasound velocity measurements is an added benefit of our reconstruction method. Multigate pulsed Doppler ultrasound scanners offer powerful capabilities to noninvasively and nonintrusively measure velocity profiles for hemodynamic and other fluid flow applications. This flow reconstruction method can also be tailored for use with other flow diagnostic modalities, such as magnetic resonance imaging (MRI) and a wide class of optical methods.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleApplication of Womersley Model to Reconstruct Pulsatile Flow From Doppler Ultrasound Measurements
    typeJournal Paper
    journal volume136
    journal issue4
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4026481
    journal fristpage41102
    journal lastpage41102
    identifier eissn1528-901X
    treeJournal of Fluids Engineering:;2014:;volume( 136 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian