| contributor author | Lorenz, M. | |
| contributor author | Horbach, T. | |
| contributor author | Schulz, A. | |
| contributor author | Bauer, H. | |
| date accessioned | 2017-05-09T01:03:06Z | |
| date available | 2017-05-09T01:03:06Z | |
| date issued | 2013 | |
| identifier issn | 0889-504X | |
| identifier other | turb_135_3_031003.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/153323 | |
| description abstract | A novel method for surface temperature measurement using temperature sensitive paint (TSP) is presented. Precalibration of the TSP is shown and a semi in situ calibration technique using thermocouples is provided for high accuracy measurement. The method presented is applied to a film cooling experiment with a maximum surface temperature of 430 K and compared to highly reliable infrared thermography measurements that serve as benchmark results. The in situ calibration technique shows a maximum deviation of 0.5 K from the thermocouple readings. The comparison of laterally averaged temperature distributions of TSP and infrared measurement shows excellent agreement. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A Novel Measuring Technique Utilizing Temperature Sensitive Paint—Measurement Procedure, Validation, Application, and Comparison With Infrared Thermography | |
| type | Journal Paper | |
| journal volume | 135 | |
| journal issue | 3 | |
| journal title | Journal of Turbomachinery | |
| identifier doi | 10.1115/1.4006638 | |
| journal fristpage | 31003 | |
| journal lastpage | 31003 | |
| identifier eissn | 1528-8900 | |
| tree | Journal of Turbomachinery:;2013:;volume( 135 ):;issue: 003 | |
| contenttype | Fulltext | |