Evaluation of Steam Washers in Power-Plant BoilersSource: Journal of Engineering for Gas Turbines and Power:;1961:;volume( 083 ):;issue: 004::page 343Author:H. A. Klein
DOI: 10.1115/1.3673204Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: A research program was undertaken to study the feasibility of employing steam washers to control silica deposition in high-pressure turbines. Under certain laboratory conditions, steam washing was found to be effective; however, its useful application appears to be limited to a very small number of power stations. Space limitations in modern boiler drums make it difficult to install the bulky equipment without interfering with flow and distribution through the drum. A washer installation can actually be the cause of mechanical carry-over. The use of high-quality make-up water and the prevention of raw-water contamination provide a more economical and trouble-free solution to the silica problem. A steam washer has little practical value in plants where good external control of silica is practiced.
keyword(s): Boilers , Power stations , Steam , Water , Flow (Dynamics) , High pressure (Physics) , Contamination , Turbines AND Industrial plants ,
|
Show full item record
| contributor author | H. A. Klein | |
| date accessioned | 2017-05-09T00:59:35Z | |
| date available | 2017-05-09T00:59:35Z | |
| date copyright | October, 1961 | |
| date issued | 1961 | |
| identifier issn | 1528-8919 | |
| identifier other | JETPEZ-26619#343_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/152055 | |
| description abstract | A research program was undertaken to study the feasibility of employing steam washers to control silica deposition in high-pressure turbines. Under certain laboratory conditions, steam washing was found to be effective; however, its useful application appears to be limited to a very small number of power stations. Space limitations in modern boiler drums make it difficult to install the bulky equipment without interfering with flow and distribution through the drum. A washer installation can actually be the cause of mechanical carry-over. The use of high-quality make-up water and the prevention of raw-water contamination provide a more economical and trouble-free solution to the silica problem. A steam washer has little practical value in plants where good external control of silica is practiced. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Evaluation of Steam Washers in Power-Plant Boilers | |
| type | Journal Paper | |
| journal volume | 83 | |
| journal issue | 4 | |
| journal title | Journal of Engineering for Gas Turbines and Power | |
| identifier doi | 10.1115/1.3673204 | |
| journal fristpage | 343 | |
| journal lastpage | 350 | |
| identifier eissn | 0742-4795 | |
| keywords | Boilers | |
| keywords | Power stations | |
| keywords | Steam | |
| keywords | Water | |
| keywords | Flow (Dynamics) | |
| keywords | High pressure (Physics) | |
| keywords | Contamination | |
| keywords | Turbines AND Industrial plants | |
| tree | Journal of Engineering for Gas Turbines and Power:;1961:;volume( 083 ):;issue: 004 | |
| contenttype | Fulltext |