    Effect of Engine Operating Conditions and Coolant Temperature on the Physical and Chemical Properties of Deposits From an Automotive Exhaust Gas Recirculation Cooler

    Source: Journal of Engineering for Gas Turbines and Power:;2013:;volume( 135 ):;issue: 002::page 22801
    Author:
    Prabhakar, Bhaskar
    ,
    Boehman, Andrأ© L.
    DOI: 10.1115/1.4007784
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The effect of engine operating conditions on exhaust gas recirculation (EGR) cooler fouling was studied using a 6.4 L V8 common rail turbodiesel engine. An experimental setup, which included a custommade shell and tube heat exchanger (EGR cooler) with six surrogate tubes, was designed to control flow variables independently. The engine was operated at 2150 rpm, 203 Nm and 1400 rpm, 81 Nm, representing medium and low load conditions, respectively, and the coolant to the heat exchanger was circulated at 85 آ°C and 40 آ°C. Heat exchanger effectiveness and pressure drop was monitored throughout the tests. Deposits from the EGR cooler were collected every 1.5 h for a total of 9 h, and their microstructure was analyzed using a scanning electron microscope while their chemical composition was analyzed using a pyrolysis GCMS apparatus, and the elemental weight percentages were obtained using a CHN analyzer. The results of these analyses showed that the effectiveness of the EGR cooler drops rapidly initially and asymptotes in a few hours. The medium load condition had a higher effectiveness loss due to a greater accumulation of deposits inside the EGR cooler, mostly due to increased thermophoresis, and produced smaller and coarse particles. The low load condition had lower effectiveness loss but produced bigger particles mostly due to excess hydrocarbons. Coolant temperature played a significant role in altering the deposit microstructure and in increasing the amount of condensed hydrocarbons. More deposits were produced for the cold coolant condition, indicating that lower coolant temperature promotes greater hydrocarbon condensation and thermophoresis. These results indicate the complex nature of fouling in automotive heat exchangers.
    • Download: (1.400Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Effect of Engine Operating Conditions and Coolant Temperature on the Physical and Chemical Properties of Deposits From an Automotive Exhaust Gas Recirculation Cooler

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/151561
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorPrabhakar, Bhaskar
    contributor authorBoehman, Andrأ© L.
    date accessioned2017-05-09T00:58:04Z
    date available2017-05-09T00:58:04Z
    date issued2013
    identifier issn1528-8919
    identifier othergtp_135_2_022801.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/151561
    description abstractThe effect of engine operating conditions on exhaust gas recirculation (EGR) cooler fouling was studied using a 6.4 L V8 common rail turbodiesel engine. An experimental setup, which included a custommade shell and tube heat exchanger (EGR cooler) with six surrogate tubes, was designed to control flow variables independently. The engine was operated at 2150 rpm, 203 Nm and 1400 rpm, 81 Nm, representing medium and low load conditions, respectively, and the coolant to the heat exchanger was circulated at 85 آ°C and 40 آ°C. Heat exchanger effectiveness and pressure drop was monitored throughout the tests. Deposits from the EGR cooler were collected every 1.5 h for a total of 9 h, and their microstructure was analyzed using a scanning electron microscope while their chemical composition was analyzed using a pyrolysis GCMS apparatus, and the elemental weight percentages were obtained using a CHN analyzer. The results of these analyses showed that the effectiveness of the EGR cooler drops rapidly initially and asymptotes in a few hours. The medium load condition had a higher effectiveness loss due to a greater accumulation of deposits inside the EGR cooler, mostly due to increased thermophoresis, and produced smaller and coarse particles. The low load condition had lower effectiveness loss but produced bigger particles mostly due to excess hydrocarbons. Coolant temperature played a significant role in altering the deposit microstructure and in increasing the amount of condensed hydrocarbons. More deposits were produced for the cold coolant condition, indicating that lower coolant temperature promotes greater hydrocarbon condensation and thermophoresis. These results indicate the complex nature of fouling in automotive heat exchangers.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEffect of Engine Operating Conditions and Coolant Temperature on the Physical and Chemical Properties of Deposits From an Automotive Exhaust Gas Recirculation Cooler
    typeJournal Paper
    journal volume135
    journal issue2
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4007784
    journal fristpage22801
    journal lastpage22801
    identifier eissn0742-4795
    treeJournal of Engineering for Gas Turbines and Power:;2013:;volume( 135 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian