| contributor author | Cassidy, Karla | |
| contributor author | Hangalur, Gajendra | |
| contributor author | Sabharwal, Preet | |
| contributor author | Chandrashekar, Naveen | |
| date accessioned | 2017-05-09T00:56:34Z | |
| date available | 2017-05-09T00:56:34Z | |
| date issued | 2013 | |
| identifier issn | 0148-0731 | |
| identifier other | bio_135_3_035001.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/151015 | |
| description abstract | The mechanism of noncontact anterior cruciate ligament (ACL) injury is not well understood. It is partly because previous studies have been unable to relate dynamic knee muscle forces during sports activities such as landing from a jump to the strain in the ACL. We present a combined in vivo/in vitro method to relate the muscle group forces to ACL strain during jumplanding using a newly developed dynamic knee simulator. A dynamic knee simulator system was designed and developed to study the sagittal plane biomechanics of the knee. The simulator is computer controlled and uses six powerful electromechanical actuators to move a cadaver knee in the sagittal plane and to apply dynamic muscle forces at the insertion sites of the quadriceps, hamstring, and gastrocnemius muscle groups and the net moment at the hip joint. In order to demonstrate the capability of the simulator to simulate dynamic sports activities on cadaver knees, motion capture of a live subject landing from a jump on a force plate was performed. The kinematics and ground reaction force data obtained from the motion capture were input into a computer based musculoskeletal lower extremity model. From the model, the forcetime profile of each muscle group across the knee during the movement was extracted, along with the motion profiles of the hip and ankle joints. This data was then programmed into the dynamic knee simulator system. Jumplanding was simulated on a cadaver knee successfully. Resulting strain in the ACL was measured using a differential variable reluctance transducer (DVRT). Our results show that the simulator has the capability to accurately simulate the dynamic sagittal plane motion and the dynamic muscle forces during jumplanding. The simulator has high repeatability. The ACL strain values agreed with the values reported in the literature. This combined in vivo/in vitro approach using this dynamic knee simulator system can be effectively used to study the relationship between sagittal plane muscle forces and ACL strain during dynamic activities. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Combined in Vivo/in Vitro Method to Study Anteriomedial Bundle Strain in the Anterior Cruciate Ligament Using a Dynamic Knee Simulator | |
| type | Journal Paper | |
| journal volume | 135 | |
| journal issue | 3 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.4023520 | |
| journal fristpage | 35001 | |
| journal lastpage | 35001 | |
| identifier eissn | 1528-8951 | |
| tree | Journal of Biomechanical Engineering:;2013:;volume( 135 ):;issue: 003 | |
| contenttype | Fulltext | |