    A Device to Control Implant and Bone-Cement Temperatures in Cemented Arthroplasty

    Source: Journal of Medical Devices:;2012:;volume( 006 ):;issue: 001::page 14503
    Author:
    A. Completo
    ,
    M. Coutinho
    ,
    M. Schiller
    ,
    A. Ramos
    ,
    C. Relvas
    ,
    J. A. Simões
    DOI: 10.1115/1.4005783
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: At present, most of the orthopaedic implants used in articular reconstruction are fixed to host bone using acrylic bone-cement. Bone-cement polymerization leads to an exothermic reaction with heat release and consequent temperature rise. The increase of temperature in the bone beyond the tolerated limits can develop osteocyte thermal necrosis and ultimately lead to bone resorption at the cement-bone interface, with subsequent loosening of the implant. Another issue that plays an important role in implant loosening is debonding of the cement from the implant initiated by crack formation at the interfacial voids. It is well established that low porosity enables better fatigue cement properties. Moderate preheating of the implant is expected to reverse the direction of polymerization, and has the ability to reduce interfacial void formation and improve interfacial shear strength. To increase the implant temperature at the initial cementing phase in order to reduce interfacial void formation, and subsequently, cool the implant in the latter cement polymerization phase to prevent the possibility of bone thermal necrosis, a new automated electronic device was designed to be use in cemented joint replacements. The developed device was specifically designed for the knee arthroplasty, namely for tibial-tray cementing. The device controls the heat flux direction between the tibial-tray and the atmosphere through the “Peltier effect,” using Peltier tablets. The device is placed on the tibial-tray during the cementing phase and starts to heat it in a first phase, promoting the polymerization that initiates at the warmer cement-implant interface. In a second phase, the heat flux in the Peltier tablets is inverted to extract the heat generated during cement polymerization. The device efficiency was evaluated by cementing several tibial-trays in bovine fresh bone and measuring the tray and cement temperatures. The temperature results in the implant and in the cement showed that the device increases and maintains the implant temperature above room temperature at the initial cementing phase, while in the subsequent phase it cools the tibial-tray and cement. Significant differences were found for peak cement temperatures between the tests performed with and without the device. The device showed its capacity to promote the beginning of cement polymerization at the implant interface contributing towards improving interfacial shear strength and in reducing the peak cement temperature in the subsequent polymerization process, thus contributing to the prevention of the bone thermal necrosis effect.
    keyword(s): Temperature , Cements (Adhesives) , Bone , Polymerization , Arthroplasty AND Heat ,
    • Download: (625.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Device to Control Implant and Bone-Cement Temperatures in Cemented Arthroplasty

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/149942
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorA. Completo
    contributor authorM. Coutinho
    contributor authorM. Schiller
    contributor authorA. Ramos
    contributor authorC. Relvas
    contributor authorJ. A. Simões
    date accessioned2017-05-09T00:53:37Z
    date available2017-05-09T00:53:37Z
    date copyrightMarch, 2012
    date issued2012
    identifier issn1932-6181
    identifier otherJMDOA4-28022#014503_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/149942
    description abstractAt present, most of the orthopaedic implants used in articular reconstruction are fixed to host bone using acrylic bone-cement. Bone-cement polymerization leads to an exothermic reaction with heat release and consequent temperature rise. The increase of temperature in the bone beyond the tolerated limits can develop osteocyte thermal necrosis and ultimately lead to bone resorption at the cement-bone interface, with subsequent loosening of the implant. Another issue that plays an important role in implant loosening is debonding of the cement from the implant initiated by crack formation at the interfacial voids. It is well established that low porosity enables better fatigue cement properties. Moderate preheating of the implant is expected to reverse the direction of polymerization, and has the ability to reduce interfacial void formation and improve interfacial shear strength. To increase the implant temperature at the initial cementing phase in order to reduce interfacial void formation, and subsequently, cool the implant in the latter cement polymerization phase to prevent the possibility of bone thermal necrosis, a new automated electronic device was designed to be use in cemented joint replacements. The developed device was specifically designed for the knee arthroplasty, namely for tibial-tray cementing. The device controls the heat flux direction between the tibial-tray and the atmosphere through the “Peltier effect,” using Peltier tablets. The device is placed on the tibial-tray during the cementing phase and starts to heat it in a first phase, promoting the polymerization that initiates at the warmer cement-implant interface. In a second phase, the heat flux in the Peltier tablets is inverted to extract the heat generated during cement polymerization. The device efficiency was evaluated by cementing several tibial-trays in bovine fresh bone and measuring the tray and cement temperatures. The temperature results in the implant and in the cement showed that the device increases and maintains the implant temperature above room temperature at the initial cementing phase, while in the subsequent phase it cools the tibial-tray and cement. Significant differences were found for peak cement temperatures between the tests performed with and without the device. The device showed its capacity to promote the beginning of cement polymerization at the implant interface contributing towards improving interfacial shear strength and in reducing the peak cement temperature in the subsequent polymerization process, thus contributing to the prevention of the bone thermal necrosis effect.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Device to Control Implant and Bone-Cement Temperatures in Cemented Arthroplasty
    typeJournal Paper
    journal volume6
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4005783
    journal fristpage14503
    identifier eissn1932-619X
    keywordsTemperature
    keywordsCements (Adhesives)
    keywordsBone
    keywordsPolymerization
    keywordsArthroplasty AND Heat
    treeJournal of Medical Devices:;2012:;volume( 006 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian