YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Mechanisms and Robotics
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Mechanisms and Robotics
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    A New 3D Mechanism for Modeling the Passive Motion of the Tibia–Fibula–Ankle Complex

    Source: Journal of Mechanisms and Robotics:;2012:;volume( 004 ):;issue: 002::page 21004
    Author:
    Benedetta Baldisserri
    ,
    Vincenzo Parenti-Castelli
    DOI: 10.1115/1.4005662
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A great number of kinematic, kinetostatic, and dynamic models of human diarthrodial joints, such as the hip, the knee, and the ankle, have been presented in the literature. On the contrary, comprehensive models of the lower limb are lacking and often oversimplify its anatomical structures by considering only 2D motion. This paper will focus on the 3D kinematic model of the articulation that involves four bones: the tibia, fibula, talus, and calcaneus. In particular, a new spatial equivalent mechanism with one degree of freedom is proposed for the passive motion simulation of this anatomical complex. The geometry of the mechanism is based on the main anatomical structures, namely the talus, the tibia, and the fibula bones at their interface, on the main ligaments of the ankle joint, and on the interosseus membrane of the leg. An iterative refinement process is presented, that provides the optimal geometry of the mechanism which allows the best fitting of simulation versus measurement data. Simulation results show the efficiency of the proposed mechanism that is believed to play an important role for future developments of models of the whole human lower limb.
    keyword(s): Motion , Mechanisms , Bone , Simulation AND Geometry ,
    • Download: (722.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A New 3D Mechanism for Modeling the Passive Motion of the Tibia–Fibula–Ankle Complex

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/149875
    Collections
    • Journal of Mechanisms and Robotics

    Show full item record

    contributor authorBenedetta Baldisserri
    contributor authorVincenzo Parenti-Castelli
    date accessioned2017-05-09T00:53:26Z
    date available2017-05-09T00:53:26Z
    date copyrightMay, 2012
    date issued2012
    identifier issn1942-4302
    identifier otherJMROA6-926064#021004_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/149875
    description abstractA great number of kinematic, kinetostatic, and dynamic models of human diarthrodial joints, such as the hip, the knee, and the ankle, have been presented in the literature. On the contrary, comprehensive models of the lower limb are lacking and often oversimplify its anatomical structures by considering only 2D motion. This paper will focus on the 3D kinematic model of the articulation that involves four bones: the tibia, fibula, talus, and calcaneus. In particular, a new spatial equivalent mechanism with one degree of freedom is proposed for the passive motion simulation of this anatomical complex. The geometry of the mechanism is based on the main anatomical structures, namely the talus, the tibia, and the fibula bones at their interface, on the main ligaments of the ankle joint, and on the interosseus membrane of the leg. An iterative refinement process is presented, that provides the optimal geometry of the mechanism which allows the best fitting of simulation versus measurement data. Simulation results show the efficiency of the proposed mechanism that is believed to play an important role for future developments of models of the whole human lower limb.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA New 3D Mechanism for Modeling the Passive Motion of the Tibia–Fibula–Ankle Complex
    typeJournal Paper
    journal volume4
    journal issue2
    journal titleJournal of Mechanisms and Robotics
    identifier doi10.1115/1.4005662
    journal fristpage21004
    identifier eissn1942-4310
    keywordsMotion
    keywordsMechanisms
    keywordsBone
    keywordsSimulation AND Geometry
    treeJournal of Mechanisms and Robotics:;2012:;volume( 004 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian