    Effects Due to the Temperature Measurement Section on the Performance Estimation of a Centrifugal Compressor Stage

    Source: Journal of Engineering for Gas Turbines and Power:;2012:;volume( 134 ):;issue: 003::page 32402
    Author:
    Alessandro Bianchini
    ,
    Giovanni Ferrara
    ,
    Lorenzo Ferrari
    ,
    Valeria Ballarini
    ,
    Lorenzo Bianchi
    ,
    Libero Tapinassi
    ,
    Lorenzo Toni
    DOI: 10.1115/1.4004722
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A wide-ranging analysis was performed by GE Oil & Gas and the University of Florence to investigate the effects on the estimation of centrifugal compressor performance induced by a different choice of the total temperature measurement section. With this goal in mind, the study focused on the analysis of a commonly found discrepancy between the measurements at the impeller outlet section and at the stage exit section. Based on the experimental data collected on a centrifugal impeller, three main physical phenomena were analyzed and discussed in further detail. First, the effect of the heat exchange was examined, and its influence on the total temperature variation throughout the machine was extrapolated. Next, the influence of the heat-exchange phenomena affecting the temperature sensors was evaluated by means of numerical models and physical assumptions. Finally, the effects on the temperature measurement of the flow structure at the impeller outlet were investigated. In particular, a corrective model to account for the thermal inertia of the thermocouples normally applied in this section was applied to the experimental data. The corrected temperatures at the investigated measurement sections were then compared, and their influence on the correct stage performance estimation is discussed in this study.
    keyword(s): Flow (Dynamics) , Heat , Temperature , Temperature measurement , Compressors , Errors , Thermocouples , Impellers , Sensors AND Probes ,
    • Download: (1.547Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Effects Due to the Temperature Measurement Section on the Performance Estimation of a Centrifugal Compressor Stage

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/148896
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorAlessandro Bianchini
    contributor authorGiovanni Ferrara
    contributor authorLorenzo Ferrari
    contributor authorValeria Ballarini
    contributor authorLorenzo Bianchi
    contributor authorLibero Tapinassi
    contributor authorLorenzo Toni
    date accessioned2017-05-09T00:50:31Z
    date available2017-05-09T00:50:31Z
    date copyrightMarch, 2012
    date issued2012
    identifier issn1528-8919
    identifier otherJETPEZ-27186#032402_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148896
    description abstractA wide-ranging analysis was performed by GE Oil & Gas and the University of Florence to investigate the effects on the estimation of centrifugal compressor performance induced by a different choice of the total temperature measurement section. With this goal in mind, the study focused on the analysis of a commonly found discrepancy between the measurements at the impeller outlet section and at the stage exit section. Based on the experimental data collected on a centrifugal impeller, three main physical phenomena were analyzed and discussed in further detail. First, the effect of the heat exchange was examined, and its influence on the total temperature variation throughout the machine was extrapolated. Next, the influence of the heat-exchange phenomena affecting the temperature sensors was evaluated by means of numerical models and physical assumptions. Finally, the effects on the temperature measurement of the flow structure at the impeller outlet were investigated. In particular, a corrective model to account for the thermal inertia of the thermocouples normally applied in this section was applied to the experimental data. The corrected temperatures at the investigated measurement sections were then compared, and their influence on the correct stage performance estimation is discussed in this study.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEffects Due to the Temperature Measurement Section on the Performance Estimation of a Centrifugal Compressor Stage
    typeJournal Paper
    journal volume134
    journal issue3
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4004722
    journal fristpage32402
    identifier eissn0742-4795
    keywordsFlow (Dynamics)
    keywordsHeat
    keywordsTemperature
    keywordsTemperature measurement
    keywordsCompressors
    keywordsErrors
    keywordsThermocouples
    keywordsImpellers
    keywordsSensors AND Probes
    treeJournal of Engineering for Gas Turbines and Power:;2012:;volume( 134 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian