    Development of a Non-Blood Contacting Cardiac Assist and Support Device: An In Vivo Proof of Concept Study

    Source: Journal of Medical Devices:;2011:;volume( 005 ):;issue: 004::page 41007
    Author:
    Michael R. Moreno
    ,
    Saurabh Biswas
    ,
    Lewis D. Harrison
    ,
    Matthew W. Miller
    ,
    David A. Nelson
    ,
    John C. Criscione
    ,
    Theresa W. Fossum
    ,
    Guilluame Pernelle
    DOI: 10.1115/1.4005281
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: One of the maladaptive changes following a heart attack is an initial decline in pumping capacity, which leads to activation of compensatory mechanisms, and subsequently, a phenomenon known as cardiac or left ventricular remodeling. Evidence suggests that mechanical cues are critical in the progression of congestive heart failure. In order to mediate two important mechanical parameters, cardiac size and cardiac output, we have developed a direct cardiac contact device capable of two actions: (1) adjustable cardiac support to modulate cardiac size and (2) synchronous active assist to modulate cardiac output. In addition, the device was designed to (1) remain in place about the heart without tethering, (2) allow free normal motion of the heart, and (3) provide assist via direct cardiac compression without abnormally inverting the curvature of the heart. The actions and features described above were mapped to particular design solutions and assessed in an acute implantation in an ovine model of acute heart failure (esmolol overdose). A balloon catheter was inflated in the vena cava to reduce preload and determine the end-diastolic pressure-volume relationship with and without passive support. A Millar PV Loop catheter was inserted in the left ventricle to acquire pressure-volume data throughout the experiments. Fluoroscopic imaging was used to investigate effects on cardiac motion. Implementation of the adjustable passive support function of the device successfully modulated the end-diastolic pressure-volume relationship toward normal. The active assist function successfully restored cardiac output and stroke work to healthy baseline levels in the esmolol induced failure model. The device remained in place throughout the experiment and when de-activated, did not inhibit cardiac motion. In this in vivo proof of concept study, we have demonstrated that a single device can be used to provide both passive constraint/support and active assist. Such a device may allow for controlled, disease specific, flexible intervention. Ultimately, it is hypothesized that the combination of support and assist could be used to facilitate cardiac rehabilitation therapy. The principles guiding this approach involve simply creating the conditions under which natural growth and remodeling processes are guided in a therapeutic manner. For example, the passive support function could be incrementally adjusted to gradually reduce the size of the dilated myocardium, while the active assist function can be implemented as necessary to maintain cardiac output and decompress the heart.
    keyword(s): Pressure , Motion , Blood , Design , Diseases , Failure , Patient treatment , Compression , Myocardium , Catheters AND Imaging ,
    • Download: (1.508Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Development of a Non-Blood Contacting Cardiac Assist and Support Device: An In Vivo Proof of Concept Study

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/147197
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorMichael R. Moreno
    contributor authorSaurabh Biswas
    contributor authorLewis D. Harrison
    contributor authorMatthew W. Miller
    contributor authorDavid A. Nelson
    contributor authorJohn C. Criscione
    contributor authorTheresa W. Fossum
    contributor authorGuilluame Pernelle
    date accessioned2017-05-09T00:46:07Z
    date available2017-05-09T00:46:07Z
    date copyrightDecember, 2011
    date issued2011
    identifier issn1932-6181
    identifier otherJMDOA4-28021#041007_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/147197
    description abstractOne of the maladaptive changes following a heart attack is an initial decline in pumping capacity, which leads to activation of compensatory mechanisms, and subsequently, a phenomenon known as cardiac or left ventricular remodeling. Evidence suggests that mechanical cues are critical in the progression of congestive heart failure. In order to mediate two important mechanical parameters, cardiac size and cardiac output, we have developed a direct cardiac contact device capable of two actions: (1) adjustable cardiac support to modulate cardiac size and (2) synchronous active assist to modulate cardiac output. In addition, the device was designed to (1) remain in place about the heart without tethering, (2) allow free normal motion of the heart, and (3) provide assist via direct cardiac compression without abnormally inverting the curvature of the heart. The actions and features described above were mapped to particular design solutions and assessed in an acute implantation in an ovine model of acute heart failure (esmolol overdose). A balloon catheter was inflated in the vena cava to reduce preload and determine the end-diastolic pressure-volume relationship with and without passive support. A Millar PV Loop catheter was inserted in the left ventricle to acquire pressure-volume data throughout the experiments. Fluoroscopic imaging was used to investigate effects on cardiac motion. Implementation of the adjustable passive support function of the device successfully modulated the end-diastolic pressure-volume relationship toward normal. The active assist function successfully restored cardiac output and stroke work to healthy baseline levels in the esmolol induced failure model. The device remained in place throughout the experiment and when de-activated, did not inhibit cardiac motion. In this in vivo proof of concept study, we have demonstrated that a single device can be used to provide both passive constraint/support and active assist. Such a device may allow for controlled, disease specific, flexible intervention. Ultimately, it is hypothesized that the combination of support and assist could be used to facilitate cardiac rehabilitation therapy. The principles guiding this approach involve simply creating the conditions under which natural growth and remodeling processes are guided in a therapeutic manner. For example, the passive support function could be incrementally adjusted to gradually reduce the size of the dilated myocardium, while the active assist function can be implemented as necessary to maintain cardiac output and decompress the heart.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment of a Non-Blood Contacting Cardiac Assist and Support Device: An In Vivo Proof of Concept Study
    typeJournal Paper
    journal volume5
    journal issue4
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4005281
    journal fristpage41007
    identifier eissn1932-619X
    keywordsPressure
    keywordsMotion
    keywordsBlood
    keywordsDesign
    keywordsDiseases
    keywordsFailure
    keywordsPatient treatment
    keywordsCompression
    keywordsMyocardium
    keywordsCatheters AND Imaging
    treeJournal of Medical Devices:;2011:;volume( 005 ):;issue: 004
    contenttypeFulltext