    Design and Experimental Assessment of an Elastically Averaged Binary Manipulator Using Pneumatic Air Muscles for Magnetic Resonance Imaging Guided Prostate Interventions

    Source: Journal of Mechanical Design:;2011:;volume( 133 ):;issue: 011::page 111011
    Author:
    Sylvain Proulx
    ,
    Jean-Sébastien Plante
    DOI: 10.1115/1.4004983
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Early diagnostic and treatment of prostate cancer could be achieved using magnetic resonance imaging (MRI) to improve tumor perceptibility. Nonetheless, performing intra-MRI interventions present significant challenges due to intense magnetic fields and limited patient access. This paper presents an MRI-compatible manipulator using elastically averaged binary pneumatic air muscles (PAMs) to orient a needle into a targeted region of the prostate under the command of a physician. The proposed manipulator is based on an all-polymer compliant mechanism designed to make a completely MRI-compatible positioning system. A model based on the PAMs deformation energy is used to design the manipulator so that its discrete workspace, stiffness, and size meet clinically relevant design requirements. The model is also used to study the motion of the device during a state shift. A laboratory prototype of the device shows that the covered workspace, stiffness, and size of the manipulator can meet clinical requirements. Repeatability and accuracy are also acceptable with values of 0.5 mm and 1.7 mm, respectively. Finally, the manipulator’s behavior during state shift describes a hook-shaped motion that is both analytically predicted and experimentally observed.
    keyword(s): Trajectories (Physics) , Design , Magnetic resonance imaging , Errors , Manipulators , Muscle , Stiffness , needles AND End effectors ,
    • Download: (1.836Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Design and Experimental Assessment of an Elastically Averaged Binary Manipulator Using Pneumatic Air Muscles for Magnetic Resonance Imaging Guided Prostate Interventions

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/146967
    Collections
    • Journal of Mechanical Design

    Show full item record

    contributor authorSylvain Proulx
    contributor authorJean-Sébastien Plante
    date accessioned2017-05-09T00:45:39Z
    date available2017-05-09T00:45:39Z
    date copyrightNovember, 2011
    date issued2011
    identifier issn1050-0472
    identifier otherJMDEDB-27955#111011_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/146967
    description abstractEarly diagnostic and treatment of prostate cancer could be achieved using magnetic resonance imaging (MRI) to improve tumor perceptibility. Nonetheless, performing intra-MRI interventions present significant challenges due to intense magnetic fields and limited patient access. This paper presents an MRI-compatible manipulator using elastically averaged binary pneumatic air muscles (PAMs) to orient a needle into a targeted region of the prostate under the command of a physician. The proposed manipulator is based on an all-polymer compliant mechanism designed to make a completely MRI-compatible positioning system. A model based on the PAMs deformation energy is used to design the manipulator so that its discrete workspace, stiffness, and size meet clinically relevant design requirements. The model is also used to study the motion of the device during a state shift. A laboratory prototype of the device shows that the covered workspace, stiffness, and size of the manipulator can meet clinical requirements. Repeatability and accuracy are also acceptable with values of 0.5 mm and 1.7 mm, respectively. Finally, the manipulator’s behavior during state shift describes a hook-shaped motion that is both analytically predicted and experimentally observed.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign and Experimental Assessment of an Elastically Averaged Binary Manipulator Using Pneumatic Air Muscles for Magnetic Resonance Imaging Guided Prostate Interventions
    typeJournal Paper
    journal volume133
    journal issue11
    journal titleJournal of Mechanical Design
    identifier doi10.1115/1.4004983
    journal fristpage111011
    identifier eissn1528-9001
    keywordsTrajectories (Physics)
    keywordsDesign
    keywordsMagnetic resonance imaging
    keywordsErrors
    keywordsManipulators
    keywordsMuscle
    keywordsStiffness
    keywordsneedles AND End effectors
    treeJournal of Mechanical Design:;2011:;volume( 133 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian