    Flow and Particle Dispersion in Lung Acini: Effect of Geometric and Dynamic Parameters During Synchronous Ventilation

    Source: Journal of Fluids Engineering:;2011:;volume( 133 ):;issue: 007::page 71001
    Author:
    Sudhaker Chhabra
    ,
    Ajay K Prasad
    DOI: 10.1115/1.4004362
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The human lung comprises about 300 million alveoli which are located on bronchioles between the 17th to 24th generations of the acinar tree, with a progressively higher population density in the deeper branches (lower acini). The alveolar size and aspect ratio change with generation number. Due to successive bifurcation, the flow velocity magnitude also decreases as the bronchiole diameter decreases from the upper to lower acini. As a result, fluid dynamic parameters such as Reynolds (Re) and Womersley (α) numbers progressively decrease with increasing generation number. In order to characterize alveolar flow patterns and inhaled particle transport during synchronous ventilation, we have conducted measurements for a range of dimensionless parameters physiologically relevant to the upper acini. Acinar airflow patterns were measured using a simplified in vitro alveolar model consisting of a single transparent elastic truncated sphere (representing the alveolus) mounted over a circular hole on the side of a rigid circular tube (representing the bronchiole). The model alveolus was capable of expanding and contracting in-phase with the oscillatory flow through the bronchiole thereby simulating synchronous ventilation. Realistic breathing conditions were achieved by exercising the model over a range of progressively varying geometric and dynamic parameters to simulate the environment within several generations of the acinar tree. Particle image velocimetry was used to measure the resulting flow patterns. Next, we used the measured flow fields to calculate particle trajectories to obtain particle transport and deposition statistics for massless and finite-size particles under the influence of flow advection and gravity. Our study shows that the geometric parameters (β and ΔV/V) primarily affect the velocity magnitudes, whereas the dynamic parameters (Re and α) distort the flow symmetry while also altering the velocity magnitudes. Consequently, the dynamic parameters have a greater influence on the particle trajectories and deposition statistics compared to the geometric parameters. The results from this study can benefit pulmonary research into the risk assessment of toxicological inhaled aerosols, and the pharmaceutical industry by providing better insight into the flow patterns and particle transport of inhalable therapeutics in the acini.
    keyword(s): Flow (Dynamics) , Particulate matter , Gravity (Force) AND Lung ,
    • Download: (6.125Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Flow and Particle Dispersion in Lung Acini: Effect of Geometric and Dynamic Parameters During Synchronous Ventilation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/146305
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorSudhaker Chhabra
    contributor authorAjay K Prasad
    date accessioned2017-05-09T00:44:15Z
    date available2017-05-09T00:44:15Z
    date copyrightJuly, 2011
    date issued2011
    identifier issn0098-2202
    identifier otherJFEGA4-27474#071001_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/146305
    description abstractThe human lung comprises about 300 million alveoli which are located on bronchioles between the 17th to 24th generations of the acinar tree, with a progressively higher population density in the deeper branches (lower acini). The alveolar size and aspect ratio change with generation number. Due to successive bifurcation, the flow velocity magnitude also decreases as the bronchiole diameter decreases from the upper to lower acini. As a result, fluid dynamic parameters such as Reynolds (Re) and Womersley (α) numbers progressively decrease with increasing generation number. In order to characterize alveolar flow patterns and inhaled particle transport during synchronous ventilation, we have conducted measurements for a range of dimensionless parameters physiologically relevant to the upper acini. Acinar airflow patterns were measured using a simplified in vitro alveolar model consisting of a single transparent elastic truncated sphere (representing the alveolus) mounted over a circular hole on the side of a rigid circular tube (representing the bronchiole). The model alveolus was capable of expanding and contracting in-phase with the oscillatory flow through the bronchiole thereby simulating synchronous ventilation. Realistic breathing conditions were achieved by exercising the model over a range of progressively varying geometric and dynamic parameters to simulate the environment within several generations of the acinar tree. Particle image velocimetry was used to measure the resulting flow patterns. Next, we used the measured flow fields to calculate particle trajectories to obtain particle transport and deposition statistics for massless and finite-size particles under the influence of flow advection and gravity. Our study shows that the geometric parameters (β and ΔV/V) primarily affect the velocity magnitudes, whereas the dynamic parameters (Re and α) distort the flow symmetry while also altering the velocity magnitudes. Consequently, the dynamic parameters have a greater influence on the particle trajectories and deposition statistics compared to the geometric parameters. The results from this study can benefit pulmonary research into the risk assessment of toxicological inhaled aerosols, and the pharmaceutical industry by providing better insight into the flow patterns and particle transport of inhalable therapeutics in the acini.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleFlow and Particle Dispersion in Lung Acini: Effect of Geometric and Dynamic Parameters During Synchronous Ventilation
    typeJournal Paper
    journal volume133
    journal issue7
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4004362
    journal fristpage71001
    identifier eissn1528-901X
    keywordsFlow (Dynamics)
    keywordsParticulate matter
    keywordsGravity (Force) AND Lung
    treeJournal of Fluids Engineering:;2011:;volume( 133 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian