Subcooled Water Flow Boiling Heat Transfer in a Short SUS304-Tube With Twisted-Tape InsertSource: Journal of Engineering for Gas Turbines and Power:;2011:;volume( 133 ):;issue: 005::page 52906DOI: 10.1115/1.4002405Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The subcooled boiling heat transfer and the steady-state critical heat fluxes (CHFs) in a short SUS304-tube with twisted-tape insert are systematically measured for mass velocities (G=4016–13,850 kg/m2 s), inlet liquid temperatures (Tin=285.82–363.96 K), outlet pressures (Pout=764.76–889.02 kPa), and exponentially increasing heat input (Q=Q0 exp(t/τ), τ=8.5 s) by the experimental water loop comprised of a multistage canned-type circulation pump controlled by an inverter. The SUS304 test tube of inner diameter (d=6 mm), heated length (L=59.5 mm), effective length (Leff=49.1 mm), L/d(=9.92), Leff/d(=8.18), and wall thickness (δ=0.5 mm) with average surface roughness (Ra=3.18 μm) is used in this work. The SUS304 twisted tape with twist ratio, y(=H/d=(pitch of 180 deg rotation)/d), of 3.39 is used. The relation between inner surface temperature and heat flux for the SUS304-tube with the twisted-tape insert are clarified from nonboiling to CHF. The subcooled boiling heat transfer for SUS304-tube with the twisted-tape insert is compared with our empty SUS304-tube data and the values calculated by our and other workers’ correlations for the subcooled boiling heat transfer. The influences of the twisted-tape insert and the swirl velocity on the subcooled boiling heat transfer and the CHFs are investigated into details and the widely and precisely predictable correlations of the subcooled boiling heat transfer and the CHFs for turbulent flow of water in the SUS304-tube with twisted-tape insert are given based on the experimental data. The correlations can describe the subcooled boiling heat transfer coefficients and the CHFs obtained in this work within −25 to +15% difference.
keyword(s): Flow (Dynamics) , Temperature , Heat transfer , Boiling , Steady state , Subcooling , Water , Critical heat flux , Surface roughness , Heat , Heat flux AND Pressure ,
|
Show full item record
| contributor author | Koichi Hata | |
| contributor author | Suguru Masuzaki | |
| date accessioned | 2017-05-09T00:43:41Z | |
| date available | 2017-05-09T00:43:41Z | |
| date copyright | May, 2011 | |
| date issued | 2011 | |
| identifier issn | 1528-8919 | |
| identifier other | JETPEZ-27163#052906_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/146027 | |
| description abstract | The subcooled boiling heat transfer and the steady-state critical heat fluxes (CHFs) in a short SUS304-tube with twisted-tape insert are systematically measured for mass velocities (G=4016–13,850 kg/m2 s), inlet liquid temperatures (Tin=285.82–363.96 K), outlet pressures (Pout=764.76–889.02 kPa), and exponentially increasing heat input (Q=Q0 exp(t/τ), τ=8.5 s) by the experimental water loop comprised of a multistage canned-type circulation pump controlled by an inverter. The SUS304 test tube of inner diameter (d=6 mm), heated length (L=59.5 mm), effective length (Leff=49.1 mm), L/d(=9.92), Leff/d(=8.18), and wall thickness (δ=0.5 mm) with average surface roughness (Ra=3.18 μm) is used in this work. The SUS304 twisted tape with twist ratio, y(=H/d=(pitch of 180 deg rotation)/d), of 3.39 is used. The relation between inner surface temperature and heat flux for the SUS304-tube with the twisted-tape insert are clarified from nonboiling to CHF. The subcooled boiling heat transfer for SUS304-tube with the twisted-tape insert is compared with our empty SUS304-tube data and the values calculated by our and other workers’ correlations for the subcooled boiling heat transfer. The influences of the twisted-tape insert and the swirl velocity on the subcooled boiling heat transfer and the CHFs are investigated into details and the widely and precisely predictable correlations of the subcooled boiling heat transfer and the CHFs for turbulent flow of water in the SUS304-tube with twisted-tape insert are given based on the experimental data. The correlations can describe the subcooled boiling heat transfer coefficients and the CHFs obtained in this work within −25 to +15% difference. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Subcooled Water Flow Boiling Heat Transfer in a Short SUS304-Tube With Twisted-Tape Insert | |
| type | Journal Paper | |
| journal volume | 133 | |
| journal issue | 5 | |
| journal title | Journal of Engineering for Gas Turbines and Power | |
| identifier doi | 10.1115/1.4002405 | |
| journal fristpage | 52906 | |
| identifier eissn | 0742-4795 | |
| keywords | Flow (Dynamics) | |
| keywords | Temperature | |
| keywords | Heat transfer | |
| keywords | Boiling | |
| keywords | Steady state | |
| keywords | Subcooling | |
| keywords | Water | |
| keywords | Critical heat flux | |
| keywords | Surface roughness | |
| keywords | Heat | |
| keywords | Heat flux AND Pressure | |
| tree | Journal of Engineering for Gas Turbines and Power:;2011:;volume( 133 ):;issue: 005 | |
| contenttype | Fulltext |