    The Design of an Ambient Neutron Dose-Equivalent Meter

    Source: Journal of Engineering for Gas Turbines and Power:;2011:;volume( 133 ):;issue: 008::page 84501
    Author:
    Xia Wenming
    ,
    Guo Zhirong
    ,
    Jia Mingchun
    DOI: 10.1115/1.4002818
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: At present, most of the developed neutron dosimeters used to measure the neutron ambient dose-equivalent that has a moderator with a single counter, applied in neutron radiation fields within large range energies from thermal to MeV neutrons, are not a satisfaction to energy response. The purpose of this article is to design a suitable neutron dosimeter for radiation protection purpose. In order to overcome the disadvantage of the energy response of the neutron dosimeters combining a single sphere with a single counter, three spheres and three H3e counters were combined for the detector design. The response function of moderators with different thicknesses combined with SP9 H3e counters were calculated with Monte Carlo code MCNP 4C . The selection of three different thicknesses of the moderating polyethylene sphere was done with a MATLAB program. A suitable combination of three different thicknesses was confirmed for the detector design. The electronic system of the neutron dosimeter was introduced. The results of ambient dose-equivalent per unit fluence in different radiation areas were calculated, analyzed, and compared with the values recommended in the ISO standard. The calculated result explains that it is very significant to this design of neutron dosimeter; it may be applied to the monitor of the ambient dose in the neutron radiation fields, improving at present the status of the energy response of neutron dosimeters.
    keyword(s): Fluence (Radiation measurement) , Design , Dosimeters , Neutrons , Sensors , Neutron sources , Radiation (Physics) AND Electronics ,
    • Download: (317.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      The Design of an Ambient Neutron Dose-Equivalent Meter

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/145978
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorXia Wenming
    contributor authorGuo Zhirong
    contributor authorJia Mingchun
    date accessioned2017-05-09T00:43:34Z
    date available2017-05-09T00:43:34Z
    date copyrightAugust, 2011
    date issued2011
    identifier issn1528-8919
    identifier otherJETPEZ-27169#084501_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/145978
    description abstractAt present, most of the developed neutron dosimeters used to measure the neutron ambient dose-equivalent that has a moderator with a single counter, applied in neutron radiation fields within large range energies from thermal to MeV neutrons, are not a satisfaction to energy response. The purpose of this article is to design a suitable neutron dosimeter for radiation protection purpose. In order to overcome the disadvantage of the energy response of the neutron dosimeters combining a single sphere with a single counter, three spheres and three H3e counters were combined for the detector design. The response function of moderators with different thicknesses combined with SP9 H3e counters were calculated with Monte Carlo code MCNP 4C . The selection of three different thicknesses of the moderating polyethylene sphere was done with a MATLAB program. A suitable combination of three different thicknesses was confirmed for the detector design. The electronic system of the neutron dosimeter was introduced. The results of ambient dose-equivalent per unit fluence in different radiation areas were calculated, analyzed, and compared with the values recommended in the ISO standard. The calculated result explains that it is very significant to this design of neutron dosimeter; it may be applied to the monitor of the ambient dose in the neutron radiation fields, improving at present the status of the energy response of neutron dosimeters.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Design of an Ambient Neutron Dose-Equivalent Meter
    typeJournal Paper
    journal volume133
    journal issue8
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4002818
    journal fristpage84501
    identifier eissn0742-4795
    keywordsFluence (Radiation measurement)
    keywordsDesign
    keywordsDosimeters
    keywordsNeutrons
    keywordsSensors
    keywordsNeutron sources
    keywordsRadiation (Physics) AND Electronics
    treeJournal of Engineering for Gas Turbines and Power:;2011:;volume( 133 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian