    Experimental Investigation of a Fluidic Volume Flowmeter

    Source: Journal of Fluids Engineering:;1970:;volume( 092 ):;issue: 001::page 139
    Author:
    M. P. Wilson
    ,
    C. H. Coogan
    ,
    K. Southall
    DOI: 10.1115/1.3424922
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Tests were conducted on a fluidic oscillator for the purpose of determining its potential use as a flowmeter. Water, Bayol 35, and an ethylene glycol-water mixture were used as the test fluids. The effects of setback, aspect ratio, splitter distance, and feedback inlet location on oscillation frequency were investigated. Tests show that the oscillation frequency, when using liquids, is linearly related to volume flow rate. The tests show that the oscillation frequency was insensitive to both density and viscosity in the range investigated.
    keyword(s): Flowmeters , Oscillations , Water , Density , Flow (Dynamics) , Fluids , Viscosity , Feedback AND Mixtures ,
    • Download: (605.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimental Investigation of a Fluidic Volume Flowmeter

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/144478
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorM. P. Wilson
    contributor authorC. H. Coogan
    contributor authorK. Southall
    date accessioned2017-05-09T00:40:05Z
    date available2017-05-09T00:40:05Z
    date copyrightMarch, 1970
    date issued1970
    identifier issn0098-2202
    identifier otherJFEGA4-27360#139_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/144478
    description abstractTests were conducted on a fluidic oscillator for the purpose of determining its potential use as a flowmeter. Water, Bayol 35, and an ethylene glycol-water mixture were used as the test fluids. The effects of setback, aspect ratio, splitter distance, and feedback inlet location on oscillation frequency were investigated. Tests show that the oscillation frequency, when using liquids, is linearly related to volume flow rate. The tests show that the oscillation frequency was insensitive to both density and viscosity in the range investigated.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimental Investigation of a Fluidic Volume Flowmeter
    typeJournal Paper
    journal volume92
    journal issue1
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.3424922
    journal fristpage139
    journal lastpage142
    identifier eissn1528-901X
    keywordsFlowmeters
    keywordsOscillations
    keywordsWater
    keywordsDensity
    keywordsFlow (Dynamics)
    keywordsFluids
    keywordsViscosity
    keywordsFeedback AND Mixtures
    treeJournal of Fluids Engineering:;1970:;volume( 092 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian