    Comparison of Local Interfacial Structures Around 90 and 45-Degree Elbows in Horizontal Bubbly Flows

    Source: Journal of Fluids Engineering:;2010:;volume( 132 ):;issue: 011::page 111302
    Author:
    Mohan Yadav
    ,
    Justin D. Talley
    ,
    Seungjin Kim
    DOI: 10.1115/1.4002872
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This study presents a comparison of the geometric effects of 90 deg and 45 deg elbows in horizontal two-phase air-water bubbly flow. Two separate experiments were performed in the horizontal test section made out of 50.3 mm inner diameter glass tubes. The first set of data was collected with a 90 deg elbow installed, and then a 45 deg elbow was added to the existing facility to acquire the second set of data. A total of 15 different flow conditions, all within the bubbly flow regime, were identified for the 90 deg experiment, and very similar flow conditions were extended to the 45 deg experiment. A double-sensor conductivity probe was employed to acquire the local data at seven different axial positions along the test section, out of which four measurement locations are associated with the 90 deg experiment and three with the 45 deg experiment. The data show that the elbows have a significant effect on the development of interfacial structures as well as the bubble interaction mechanisms. Furthermore, there are characteristic similarities and differences between the effects of the two elbows. While the effect of the 45 deg elbow is evident immediately after the elbow, the 90 deg elbow effect tends to propagate further downstream of the elbow rather than immediately after the elbow. Moreover, it is shown that both elbows induce spatial oscillations in the interfacial structures and two-phase flow parameters, but the degree and the nature of oscillations differ. The effects of the elbows are also compared for the axial transport of the two-phase flow parameters.
    keyword(s): Flow (Dynamics) , Gas flow , Bubbles , Bubbly flow , Interface structure , Porosity , Two-phase flow AND Probes ,
    • Download: (1.501Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Comparison of Local Interfacial Structures Around 90 and 45-Degree Elbows in Horizontal Bubbly Flows

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/143406
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorMohan Yadav
    contributor authorJustin D. Talley
    contributor authorSeungjin Kim
    date accessioned2017-05-09T00:38:06Z
    date available2017-05-09T00:38:06Z
    date copyrightNovember, 2010
    date issued2010
    identifier issn0098-2202
    identifier otherJFEGA4-27439#111302_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/143406
    description abstractThis study presents a comparison of the geometric effects of 90 deg and 45 deg elbows in horizontal two-phase air-water bubbly flow. Two separate experiments were performed in the horizontal test section made out of 50.3 mm inner diameter glass tubes. The first set of data was collected with a 90 deg elbow installed, and then a 45 deg elbow was added to the existing facility to acquire the second set of data. A total of 15 different flow conditions, all within the bubbly flow regime, were identified for the 90 deg experiment, and very similar flow conditions were extended to the 45 deg experiment. A double-sensor conductivity probe was employed to acquire the local data at seven different axial positions along the test section, out of which four measurement locations are associated with the 90 deg experiment and three with the 45 deg experiment. The data show that the elbows have a significant effect on the development of interfacial structures as well as the bubble interaction mechanisms. Furthermore, there are characteristic similarities and differences between the effects of the two elbows. While the effect of the 45 deg elbow is evident immediately after the elbow, the 90 deg elbow effect tends to propagate further downstream of the elbow rather than immediately after the elbow. Moreover, it is shown that both elbows induce spatial oscillations in the interfacial structures and two-phase flow parameters, but the degree and the nature of oscillations differ. The effects of the elbows are also compared for the axial transport of the two-phase flow parameters.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComparison of Local Interfacial Structures Around 90 and 45-Degree Elbows in Horizontal Bubbly Flows
    typeJournal Paper
    journal volume132
    journal issue11
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4002872
    journal fristpage111302
    identifier eissn1528-901X
    keywordsFlow (Dynamics)
    keywordsGas flow
    keywordsBubbles
    keywordsBubbly flow
    keywordsInterface structure
    keywordsPorosity
    keywordsTwo-phase flow AND Probes
    treeJournal of Fluids Engineering:;2010:;volume( 132 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian