YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Finite Element Modeling of Resurfacing Hip Prosthesis: Estimation of Accuracy Through Experimental Validation

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 002::page 21002
    Author:
    Fulvia Taddei
    ,
    Saulo Martelli
    ,
    Harinderjit Singh Gill
    ,
    Luca Cristofolini
    ,
    Marco Viceconti
    DOI: 10.1115/1.4000065
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Metal-on-metal hip resurfacing is becoming increasingly popular, and a number of new devices have been recently introduced that, in the short term, appear to have satisfactory outcome but many questions are still open on the biomechanics of the resurfaced femur. This could be investigated by means of finite element analysis, but, in order to be effective in discerning potential critical conditions, the accuracy of the models’ predictions should be assessed. The major goal of this study was to validate, through a combined experimental-numerical study, a finite element modeling procedure for the simulation of resurfaced femurs. In addition, a preliminary biomechanical analysis of the changes induced in the femoral neck biomechanics by the presence of the device was performed, under a physiologic range of hip joint reaction directions. For this purpose, in vitro tests and a finite element model based on the same specimen were developed using a cadaver femur. The study focused on the Conserve Plus, one of the most common contemporary resurfacing designs. Five loading configurations were identified to correspond to the extremes of physiological directions for the hip joint. The agreement between experimental measurements and numerical predictions was good both in the prediction of the femoral strains (R2>0.9), and in the prosthesis micromotions (error<20 μm), giving confidence in the model predictions. The preliminary biomechanical analysis indicated that the strains in the femoral neck are moderately affected by the presence of the prosthesis, apart from localized strain increments that can be considerable, always predicted near the stem. Low micromotions and contact pressure were predicted, suggesting a good stability of the prosthesis. The model accuracy was good in the prediction of the femoral strains and moderately good in the prediction of the bone-prosthesis micromovements. Although the investigated loading conditions were not completely physiological, the preliminary biomechanical analysis showed relatively small changes for the proximal femur after implantation. This validated model can support realistic simulations to examine physiological load configurations and the effects of variations in prosthesis design and implantation technique.
    keyword(s): Measurement , Stress , Cements (Adhesives) , Biomechanics , Bone , Modeling , Prostheses , Finite element analysis AND Finite element model ,
    • Download: (1.038Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Finite Element Modeling of Resurfacing Hip Prosthesis: Estimation of Accuracy Through Experimental Validation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/142665
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorFulvia Taddei
    contributor authorSaulo Martelli
    contributor authorHarinderjit Singh Gill
    contributor authorLuca Cristofolini
    contributor authorMarco Viceconti
    date accessioned2017-05-09T00:36:42Z
    date available2017-05-09T00:36:42Z
    date copyrightFebruary, 2010
    date issued2010
    identifier issn0148-0731
    identifier otherJBENDY-27104#021002_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142665
    description abstractMetal-on-metal hip resurfacing is becoming increasingly popular, and a number of new devices have been recently introduced that, in the short term, appear to have satisfactory outcome but many questions are still open on the biomechanics of the resurfaced femur. This could be investigated by means of finite element analysis, but, in order to be effective in discerning potential critical conditions, the accuracy of the models’ predictions should be assessed. The major goal of this study was to validate, through a combined experimental-numerical study, a finite element modeling procedure for the simulation of resurfaced femurs. In addition, a preliminary biomechanical analysis of the changes induced in the femoral neck biomechanics by the presence of the device was performed, under a physiologic range of hip joint reaction directions. For this purpose, in vitro tests and a finite element model based on the same specimen were developed using a cadaver femur. The study focused on the Conserve Plus, one of the most common contemporary resurfacing designs. Five loading configurations were identified to correspond to the extremes of physiological directions for the hip joint. The agreement between experimental measurements and numerical predictions was good both in the prediction of the femoral strains (R2>0.9), and in the prosthesis micromotions (error<20 μm), giving confidence in the model predictions. The preliminary biomechanical analysis indicated that the strains in the femoral neck are moderately affected by the presence of the prosthesis, apart from localized strain increments that can be considerable, always predicted near the stem. Low micromotions and contact pressure were predicted, suggesting a good stability of the prosthesis. The model accuracy was good in the prediction of the femoral strains and moderately good in the prediction of the bone-prosthesis micromovements. Although the investigated loading conditions were not completely physiological, the preliminary biomechanical analysis showed relatively small changes for the proximal femur after implantation. This validated model can support realistic simulations to examine physiological load configurations and the effects of variations in prosthesis design and implantation technique.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleFinite Element Modeling of Resurfacing Hip Prosthesis: Estimation of Accuracy Through Experimental Validation
    typeJournal Paper
    journal volume132
    journal issue2
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4000065
    journal fristpage21002
    identifier eissn1528-8951
    keywordsMeasurement
    keywordsStress
    keywordsCements (Adhesives)
    keywordsBiomechanics
    keywordsBone
    keywordsModeling
    keywordsProstheses
    keywordsFinite element analysis AND Finite element model
    treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian