    Residual Stress Around the Cortical Surface in Bovine Femoral Diaphysis

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 004::page 44503
    Author:
    Satoshi Yamada
    ,
    Shigeru Tadano
    DOI: 10.1115/1.4001163
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Residual stress in living tissue plays an important role in mechanical strength. We have reported that residual stress exists in the bone tissue of a rabbit’s tibiofibula. The purpose of this study is to measure the residual stress around the outer cortical region of bovine femoral diaphysis and to discuss the distribution of the stress. This work proposed the sin2 ψ method of X-ray diffraction to the measurement of residual stresses in bone tissue. In this method, residual stress can be estimated from the variation in the interplanar spacings orientated to a number of directions without the lattice strain in the stress direction. Four-point bending tests of strip specimens taken from bovine femoral diaphysis were carried out during X-ray irradiation in advance. In the proximal, middle, and distal sections of bovine femoral diaphyses, the residual stresses at the cortical surface were measured using characteristic Mo-Kα X-rays. The bending tests of strip specimens with X-ray irradiation showed that the method could reliably estimate residual stresses in the bone tissue. The residual stress of the bone axial direction was larger than that of the circumferential direction. The stresses in the middle part of five diaphyses along the bone axial direction were tensile. The maximum stress was 162 MPa at the lateral position and the minimum was 78 MPa at the posterior position. The residual stress in the bone axial direction varies around the circumferential region. In addition, the bone axial distributions of residual stresses were different in the proximal, middle, and distal sections of the individual femur. Furthermore, it was confirmed that residual stress in the bone tissue was released by the cutting out of the specimen. The residual stresses in bone tissue could be measured by this method. The results show that residual stress in the bone axial direction at the cortical surface in bovine femoral diaphysis is tensile and varies around the circumferential region.
    keyword(s): Stress , Bone , Residual stresses AND X-rays ,
    • Download: (362.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Residual Stress Around the Cortical Surface in Bovine Femoral Diaphysis

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/142643
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorSatoshi Yamada
    contributor authorShigeru Tadano
    date accessioned2017-05-09T00:36:40Z
    date available2017-05-09T00:36:40Z
    date copyrightApril, 2010
    date issued2010
    identifier issn0148-0731
    identifier otherJBENDY-27127#044503_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142643
    description abstractResidual stress in living tissue plays an important role in mechanical strength. We have reported that residual stress exists in the bone tissue of a rabbit’s tibiofibula. The purpose of this study is to measure the residual stress around the outer cortical region of bovine femoral diaphysis and to discuss the distribution of the stress. This work proposed the sin2 ψ method of X-ray diffraction to the measurement of residual stresses in bone tissue. In this method, residual stress can be estimated from the variation in the interplanar spacings orientated to a number of directions without the lattice strain in the stress direction. Four-point bending tests of strip specimens taken from bovine femoral diaphysis were carried out during X-ray irradiation in advance. In the proximal, middle, and distal sections of bovine femoral diaphyses, the residual stresses at the cortical surface were measured using characteristic Mo-Kα X-rays. The bending tests of strip specimens with X-ray irradiation showed that the method could reliably estimate residual stresses in the bone tissue. The residual stress of the bone axial direction was larger than that of the circumferential direction. The stresses in the middle part of five diaphyses along the bone axial direction were tensile. The maximum stress was 162 MPa at the lateral position and the minimum was 78 MPa at the posterior position. The residual stress in the bone axial direction varies around the circumferential region. In addition, the bone axial distributions of residual stresses were different in the proximal, middle, and distal sections of the individual femur. Furthermore, it was confirmed that residual stress in the bone tissue was released by the cutting out of the specimen. The residual stresses in bone tissue could be measured by this method. The results show that residual stress in the bone axial direction at the cortical surface in bovine femoral diaphysis is tensile and varies around the circumferential region.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleResidual Stress Around the Cortical Surface in Bovine Femoral Diaphysis
    typeJournal Paper
    journal volume132
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4001163
    journal fristpage44503
    identifier eissn1528-8951
    keywordsStress
    keywordsBone
    keywordsResidual stresses AND X-rays
    treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian