    Finite Element Modeling of the Influence of Hand Position and Bone Properties on the Colles’ Fracture Load During a Fall

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 008::page 81007
    Author:
    Drew Buchanan
    ,
    Ani Ural
    DOI: 10.1115/1.4001681
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Distal forearm fracture is one of the most frequently observed osteoporotic fractures, which may occur as a result of low energy falls such as falls from a standing height and may be linked to the osteoporotic nature of the bone, especially in the elderly. In order to prevent the occurrence of radius fractures and their adverse outcomes, understanding the effect of both extrinsic and intrinsic contributors to fracture risk is essential. In this study, a nonlinear fracture mechanics-based finite element model is applied to human radius to assess the influence of extrinsic factors (load orientation and load distribution between scaphoid and lunate) and intrinsic bone properties (age-related changes in fracture properties and bone geometry) on the Colles’ fracture load. Seven three-dimensional finite element models of radius were created, and the fracture loads were determined by using cohesive finite element modeling, which explicitly represented the crack and the fracture process zone behavior. The simulation results showed that the load direction with respect to the longitudinal and dorsal axes of the radius influenced the fracture load. The fracture load increased with larger angles between the resultant load and the dorsal axis, and with smaller angles between the resultant load and longitudinal axis. The fracture load also varied as a function of the load ratio between the lunate and scaphoid, however, not as drastically as with the load orientation. The fracture load decreased as the load ratio (lunate/scaphoid) increased. Multiple regression analysis showed that the bone geometry and the load orientation are the most important variables that contribute to the prediction of the fracture load. The findings in this study establish a robust computational fracture risk assessment method that combines the effects of intrinsic properties of bone with extrinsic factors associated with a fall, and may be elemental in the identification of high fracture risk individuals as well as in the development of fracture prevention methods including protective falling techniques. The additional information that this study brings to fracture identification and prevention highlights the promise of fracture mechanics-based finite element modeling in fracture risk assessment.
    keyword(s): Stress , Bone , Fracture (Process) AND Geometry ,
    • Download: (521.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Finite Element Modeling of the Influence of Hand Position and Bone Properties on the Colles’ Fracture Load During a Fall

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/142569
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorDrew Buchanan
    contributor authorAni Ural
    date accessioned2017-05-09T00:36:31Z
    date available2017-05-09T00:36:31Z
    date copyrightAugust, 2010
    date issued2010
    identifier issn0148-0731
    identifier otherJBENDY-27159#081007_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142569
    description abstractDistal forearm fracture is one of the most frequently observed osteoporotic fractures, which may occur as a result of low energy falls such as falls from a standing height and may be linked to the osteoporotic nature of the bone, especially in the elderly. In order to prevent the occurrence of radius fractures and their adverse outcomes, understanding the effect of both extrinsic and intrinsic contributors to fracture risk is essential. In this study, a nonlinear fracture mechanics-based finite element model is applied to human radius to assess the influence of extrinsic factors (load orientation and load distribution between scaphoid and lunate) and intrinsic bone properties (age-related changes in fracture properties and bone geometry) on the Colles’ fracture load. Seven three-dimensional finite element models of radius were created, and the fracture loads were determined by using cohesive finite element modeling, which explicitly represented the crack and the fracture process zone behavior. The simulation results showed that the load direction with respect to the longitudinal and dorsal axes of the radius influenced the fracture load. The fracture load increased with larger angles between the resultant load and the dorsal axis, and with smaller angles between the resultant load and longitudinal axis. The fracture load also varied as a function of the load ratio between the lunate and scaphoid, however, not as drastically as with the load orientation. The fracture load decreased as the load ratio (lunate/scaphoid) increased. Multiple regression analysis showed that the bone geometry and the load orientation are the most important variables that contribute to the prediction of the fracture load. The findings in this study establish a robust computational fracture risk assessment method that combines the effects of intrinsic properties of bone with extrinsic factors associated with a fall, and may be elemental in the identification of high fracture risk individuals as well as in the development of fracture prevention methods including protective falling techniques. The additional information that this study brings to fracture identification and prevention highlights the promise of fracture mechanics-based finite element modeling in fracture risk assessment.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleFinite Element Modeling of the Influence of Hand Position and Bone Properties on the Colles’ Fracture Load During a Fall
    typeJournal Paper
    journal volume132
    journal issue8
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4001681
    journal fristpage81007
    identifier eissn1528-8951
    keywordsStress
    keywordsBone
    keywordsFracture (Process) AND Geometry
    treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian