    An Examination of the Influence of Strain Rate on Subfailure Mechanical Properties of the Annulus Fibrosus

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 009::page 91010
    Author:
    Diane E. Gregory
    ,
    Jack P. Callaghan
    DOI: 10.1115/1.4001945
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Disk herniation is often considered a cumulative injury in that repetitive stress on the posterior annulus can result in the nucleus pulposus penetrating the annulus fibrosus and eventually extruding posteriorly. Further, it has been documented that the nucleus pulposus works its way through the annulus through clefts, which form as a result of repetitive tensile strain. The annulus fibrosus is viscoelastic in nature and therefore could express different mechanical responses to applied strain at varying rates. Other viscoelastic tissues, including tendons and ligaments, have shown altered mechanical responses to different rates of applied strain, but the response of the annulus to varying rates of strain is largely unknown. The present study examined the mechanical properties of 20 two-layered samples of porcine annulus fibrosus tissue at three distinct rates of applied 20% biaxial strain (20% strain over 20 s (slow), over 10 s (medium), and over 5 s (fast)); these three rates are considered applicable to nontraumatic loading. No differences in the stiffness or maximum stress in each of the two directions of applied strain were observed between the three strain rates. Specifically, the average (standard deviation) moduli calculated at the fast, medium, and slow rates, respectively, in the axial direction were 7.42 MPa (6.06), 7.77 MPa (6.61), and 7.63 MPa (6.67) and 8.22 MPa (8.4), 8.63 MPa (9.00), and 8.49 MPa (8.69) in the circumferential direction. The maximum stress values reached during the fast, medium, and slow rates, respectively, in the axial direction were 0.40 (0.36) MPa, 0.40 (0.36) MPa, and 0.39 (0.35) MPa and 0.45 (0.47) MPa, 0.44 (0.46) MPa, and 0.43 (0.46) MPa in the circumferential direction. At submaximal strain magnitudes over a range of nontraumatic rates likely to result in clefts in the annulus and potentially leading to disk herniation, any strain rate dependence is not significant.
    keyword(s): Stress , Mechanical properties , Biological tissues AND Annulus ,
    • Download: (692.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      An Examination of the Influence of Strain Rate on Subfailure Mechanical Properties of the Annulus Fibrosus

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/142554
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorDiane E. Gregory
    contributor authorJack P. Callaghan
    date accessioned2017-05-09T00:36:29Z
    date available2017-05-09T00:36:29Z
    date copyrightSeptember, 2010
    date issued2010
    identifier issn0148-0731
    identifier otherJBENDY-27166#091010_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142554
    description abstractDisk herniation is often considered a cumulative injury in that repetitive stress on the posterior annulus can result in the nucleus pulposus penetrating the annulus fibrosus and eventually extruding posteriorly. Further, it has been documented that the nucleus pulposus works its way through the annulus through clefts, which form as a result of repetitive tensile strain. The annulus fibrosus is viscoelastic in nature and therefore could express different mechanical responses to applied strain at varying rates. Other viscoelastic tissues, including tendons and ligaments, have shown altered mechanical responses to different rates of applied strain, but the response of the annulus to varying rates of strain is largely unknown. The present study examined the mechanical properties of 20 two-layered samples of porcine annulus fibrosus tissue at three distinct rates of applied 20% biaxial strain (20% strain over 20 s (slow), over 10 s (medium), and over 5 s (fast)); these three rates are considered applicable to nontraumatic loading. No differences in the stiffness or maximum stress in each of the two directions of applied strain were observed between the three strain rates. Specifically, the average (standard deviation) moduli calculated at the fast, medium, and slow rates, respectively, in the axial direction were 7.42 MPa (6.06), 7.77 MPa (6.61), and 7.63 MPa (6.67) and 8.22 MPa (8.4), 8.63 MPa (9.00), and 8.49 MPa (8.69) in the circumferential direction. The maximum stress values reached during the fast, medium, and slow rates, respectively, in the axial direction were 0.40 (0.36) MPa, 0.40 (0.36) MPa, and 0.39 (0.35) MPa and 0.45 (0.47) MPa, 0.44 (0.46) MPa, and 0.43 (0.46) MPa in the circumferential direction. At submaximal strain magnitudes over a range of nontraumatic rates likely to result in clefts in the annulus and potentially leading to disk herniation, any strain rate dependence is not significant.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAn Examination of the Influence of Strain Rate on Subfailure Mechanical Properties of the Annulus Fibrosus
    typeJournal Paper
    journal volume132
    journal issue9
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4001945
    journal fristpage91010
    identifier eissn1528-8951
    keywordsStress
    keywordsMechanical properties
    keywordsBiological tissues AND Annulus
    treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian