YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Mathematical Modeling of the Circulation in the Liver Lobule

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 011::page 111011
    Author:
    Andrea Bonfiglio
    ,
    Kritsada Leungchavaphongse
    ,
    Rodolfo Repetto
    ,
    Jennifer H. Siggers
    DOI: 10.1115/1.4002563
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In this paper, we develop a mathematical model of blood circulation in the liver lobule. We aim to find the pressure and flux distributions within a liver lobule. We also investigate the effects of changes in pressure that occur following a resection of part of the liver, which often leads to high pressure in the portal vein. The liver can be divided into functional units called lobules. Each lobule has a hexagonal cross-section, and we assume that its longitudinal extent is large compared with its width. We consider an infinite lattice of identical lobules and study the two-dimensional flow in the hexagonal cross-sections. We model the sinusoidal space as a porous medium, with blood entering from the portal tracts (located at each of the vertices of the cross-section of the lobule) and exiting via the centrilobular vein (located in the center of the cross-section). We first develop and solve an idealized mathematical model, treating the porous medium as rigid and isotropic and blood as a Newtonian fluid. The pressure drop across the lobule and the flux of blood through the lobule are proportional to one another. In spite of its simplicity, the model gives insight into the real pressure and velocity distribution in the lobule. We then consider three modifications of the model that are designed to make it more realistic. In the first modification, we account for the fact that the sinusoids tend to be preferentially aligned in the direction of the centrilobular vein by considering an anisotropic porous medium. In the second, we account more accurately for the true behavior of the blood by using a shear-thinning model. We show that both these modifications have a small quantitative effect on the behavior but no qualitative effect. The motivation for the final modification is to understand what happens either after a partial resection of the liver or after an implantation of a liver of small size. In these cases, the pressure is observed to rise significantly, which could cause deformation of the tissue. We show that including the effects of tissue compliance in the model means that the total blood flow increases more than linearly as the pressure rises.
    keyword(s): Pressure , Flow (Dynamics) , Gates (Closures) , Blood , Liver , Blood flow , Shear (Mechanics) AND Biological tissues ,
    • Download: (703.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Mathematical Modeling of the Circulation in the Liver Lobule

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/142519
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAndrea Bonfiglio
    contributor authorKritsada Leungchavaphongse
    contributor authorRodolfo Repetto
    contributor authorJennifer H. Siggers
    date accessioned2017-05-09T00:36:25Z
    date available2017-05-09T00:36:25Z
    date copyrightNovember, 2010
    date issued2010
    identifier issn0148-0731
    identifier otherJBENDY-27177#111011_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142519
    description abstractIn this paper, we develop a mathematical model of blood circulation in the liver lobule. We aim to find the pressure and flux distributions within a liver lobule. We also investigate the effects of changes in pressure that occur following a resection of part of the liver, which often leads to high pressure in the portal vein. The liver can be divided into functional units called lobules. Each lobule has a hexagonal cross-section, and we assume that its longitudinal extent is large compared with its width. We consider an infinite lattice of identical lobules and study the two-dimensional flow in the hexagonal cross-sections. We model the sinusoidal space as a porous medium, with blood entering from the portal tracts (located at each of the vertices of the cross-section of the lobule) and exiting via the centrilobular vein (located in the center of the cross-section). We first develop and solve an idealized mathematical model, treating the porous medium as rigid and isotropic and blood as a Newtonian fluid. The pressure drop across the lobule and the flux of blood through the lobule are proportional to one another. In spite of its simplicity, the model gives insight into the real pressure and velocity distribution in the lobule. We then consider three modifications of the model that are designed to make it more realistic. In the first modification, we account for the fact that the sinusoids tend to be preferentially aligned in the direction of the centrilobular vein by considering an anisotropic porous medium. In the second, we account more accurately for the true behavior of the blood by using a shear-thinning model. We show that both these modifications have a small quantitative effect on the behavior but no qualitative effect. The motivation for the final modification is to understand what happens either after a partial resection of the liver or after an implantation of a liver of small size. In these cases, the pressure is observed to rise significantly, which could cause deformation of the tissue. We show that including the effects of tissue compliance in the model means that the total blood flow increases more than linearly as the pressure rises.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleMathematical Modeling of the Circulation in the Liver Lobule
    typeJournal Paper
    journal volume132
    journal issue11
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4002563
    journal fristpage111011
    identifier eissn1528-8951
    keywordsPressure
    keywordsFlow (Dynamics)
    keywordsGates (Closures)
    keywordsBlood
    keywordsLiver
    keywordsBlood flow
    keywordsShear (Mechanics) AND Biological tissues
    treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian