    Computationally Efficient Finite Element Evaluation of Natural Patellofemoral Mechanics

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 012::page 121013
    Author:
    Clare K. Fitzpatrick
    ,
    Mark A. Baldwin
    ,
    Paul J. Rullkoetter
    DOI: 10.1115/1.4002854
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Finite element methods have been applied to evaluate in vivo joint behavior, new devices, and surgical techniques but have typically been applied to a small or single subject cohort. Anatomic variability necessitates the use of many subject-specific models or probabilistic methods in order to adequately evaluate a device or procedure for a population. However, a fully deformable finite element model can be computationally expensive, prohibiting large multisubject or probabilistic analyses. The aim of this study was to develop a group of subject-specific models of the patellofemoral joint and evaluate trade-offs in analysis time and accuracy with fully deformable and rigid body articular cartilage representations. Finite element models of eight subjects were used to tune a pressure-overclosure relationship during a simulated deep flexion cycle. Patellofemoral kinematics and contact mechanics were evaluated and compared between a fully deformable and a rigid body analysis. Additional eight subjects were used to determine the validity of the rigid body pressure-overclosure relationship as a subject-independent parameter. There was good agreement in predicted kinematics and contact mechanics between deformable and rigid analyses for both the tuned and test groups. Root mean square differences in kinematics were less than 0.5 deg and 0.2 mm for both groups throughout flexion. Differences in contact area and peak and average contact pressures averaged 5.4%, 9.6%, and 3.8%, respectively, for the tuned group and 6.9%, 13.1%, and 6.4%, respectively, for the test group, with no significant differences between the two groups. There was a 95% reduction in computational time with the rigid body analysis as compared with the deformable analysis. The tuned pressure-overclosure relationship derived from the patellofemoral analysis was also applied to tibiofemoral (TF) articular cartilage in a group of eight subjects. Differences in contact area and peak and average contact pressures averaged 8.3%, 11.2%, and 5.7% between rigid and deformable analyses in the tibiofemoral joint. As statistical, probabilistic, and optimization techniques can require hundreds to thousands of analyses, a viable platform is crucial to component evaluation or clinical applications. The computationally efficient rigid body platform described in this study may be integrated with statistical and probabilistic methods and has potential clinical application in understanding in vivo joint mechanics on a subject-specific or population basis.
    keyword(s): Kinematics , Pressure , Contact mechanics , Finite element analysis , Finite element model , Cartilage , Cycles , Knee , Surgery , Thickness AND Joint mechanics ,
    • Download: (1.289Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Computationally Efficient Finite Element Evaluation of Natural Patellofemoral Mechanics

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/142505
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorClare K. Fitzpatrick
    contributor authorMark A. Baldwin
    contributor authorPaul J. Rullkoetter
    date accessioned2017-05-09T00:36:24Z
    date available2017-05-09T00:36:24Z
    date copyrightDecember, 2010
    date issued2010
    identifier issn0148-0731
    identifier otherJBENDY-27182#121013_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142505
    description abstractFinite element methods have been applied to evaluate in vivo joint behavior, new devices, and surgical techniques but have typically been applied to a small or single subject cohort. Anatomic variability necessitates the use of many subject-specific models or probabilistic methods in order to adequately evaluate a device or procedure for a population. However, a fully deformable finite element model can be computationally expensive, prohibiting large multisubject or probabilistic analyses. The aim of this study was to develop a group of subject-specific models of the patellofemoral joint and evaluate trade-offs in analysis time and accuracy with fully deformable and rigid body articular cartilage representations. Finite element models of eight subjects were used to tune a pressure-overclosure relationship during a simulated deep flexion cycle. Patellofemoral kinematics and contact mechanics were evaluated and compared between a fully deformable and a rigid body analysis. Additional eight subjects were used to determine the validity of the rigid body pressure-overclosure relationship as a subject-independent parameter. There was good agreement in predicted kinematics and contact mechanics between deformable and rigid analyses for both the tuned and test groups. Root mean square differences in kinematics were less than 0.5 deg and 0.2 mm for both groups throughout flexion. Differences in contact area and peak and average contact pressures averaged 5.4%, 9.6%, and 3.8%, respectively, for the tuned group and 6.9%, 13.1%, and 6.4%, respectively, for the test group, with no significant differences between the two groups. There was a 95% reduction in computational time with the rigid body analysis as compared with the deformable analysis. The tuned pressure-overclosure relationship derived from the patellofemoral analysis was also applied to tibiofemoral (TF) articular cartilage in a group of eight subjects. Differences in contact area and peak and average contact pressures averaged 8.3%, 11.2%, and 5.7% between rigid and deformable analyses in the tibiofemoral joint. As statistical, probabilistic, and optimization techniques can require hundreds to thousands of analyses, a viable platform is crucial to component evaluation or clinical applications. The computationally efficient rigid body platform described in this study may be integrated with statistical and probabilistic methods and has potential clinical application in understanding in vivo joint mechanics on a subject-specific or population basis.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComputationally Efficient Finite Element Evaluation of Natural Patellofemoral Mechanics
    typeJournal Paper
    journal volume132
    journal issue12
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4002854
    journal fristpage121013
    identifier eissn1528-8951
    keywordsKinematics
    keywordsPressure
    keywordsContact mechanics
    keywordsFinite element analysis
    keywordsFinite element model
    keywordsCartilage
    keywordsCycles
    keywordsKnee
    keywordsSurgery
    keywordsThickness AND Joint mechanics
    treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian