    A Microfluidic Device to Establish Concentration Gradients Using Reagent Density Differences

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 012::page 121012
    Author:
    Qingjun Kong
    ,
    Richard A. Able
    ,
    Veronica Dudu
    ,
    Maribel Vazquez
    DOI: 10.1115/1.4002797
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Microfabrication has become widely utilized to generate controlled microenvironments that establish chemical concentration gradients for a variety of engineering and life science applications. To establish microfluidic flow, the majority of existing devices rely upon additional facilities, equipment, and excessive reagent supplies, which together limit device portability as well as constrain device usage to individuals trained in technological disciplines. The current work presents our laboratory-developed bridged μLane system, which is a stand-alone device that runs via conventional pipette loading and can operate for several days without need of external machinery or additional reagent volumes. The bridged μLane is a two-layer polydimethylsiloxane microfluidic device that is able to establish controlled chemical concentration gradients over time by relying solely upon differences in reagent densities. Fluorescently labeled Dextran was used to validate the design and operation of the bridged μLane by evaluating experimentally measured transport properties within the microsystem in conjunction with numerical simulations and established mathematical transport models. Results demonstrate how the bridged μLane system was used to generate spatial concentration gradients that resulted in an experimentally measured Dextran diffusivity of (0.82±0.01)×10−6 cm2/s.
    keyword(s): Density , Flow (Dynamics) , Channels (Hydraulic engineering) , Manufacturing , Plasma desorption mass spectrometry , Microfluidics , Gradients , Microchannels , Design , Diffusion (Physics) , Computer simulation , Microelectromechanical systems AND Modeling ,
    • Download: (908.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Microfluidic Device to Establish Concentration Gradients Using Reagent Density Differences

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/142504
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorQingjun Kong
    contributor authorRichard A. Able
    contributor authorVeronica Dudu
    contributor authorMaribel Vazquez
    date accessioned2017-05-09T00:36:23Z
    date available2017-05-09T00:36:23Z
    date copyrightDecember, 2010
    date issued2010
    identifier issn0148-0731
    identifier otherJBENDY-27182#121012_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142504
    description abstractMicrofabrication has become widely utilized to generate controlled microenvironments that establish chemical concentration gradients for a variety of engineering and life science applications. To establish microfluidic flow, the majority of existing devices rely upon additional facilities, equipment, and excessive reagent supplies, which together limit device portability as well as constrain device usage to individuals trained in technological disciplines. The current work presents our laboratory-developed bridged μLane system, which is a stand-alone device that runs via conventional pipette loading and can operate for several days without need of external machinery or additional reagent volumes. The bridged μLane is a two-layer polydimethylsiloxane microfluidic device that is able to establish controlled chemical concentration gradients over time by relying solely upon differences in reagent densities. Fluorescently labeled Dextran was used to validate the design and operation of the bridged μLane by evaluating experimentally measured transport properties within the microsystem in conjunction with numerical simulations and established mathematical transport models. Results demonstrate how the bridged μLane system was used to generate spatial concentration gradients that resulted in an experimentally measured Dextran diffusivity of (0.82±0.01)×10−6 cm2/s.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Microfluidic Device to Establish Concentration Gradients Using Reagent Density Differences
    typeJournal Paper
    journal volume132
    journal issue12
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4002797
    journal fristpage121012
    identifier eissn1528-8951
    keywordsDensity
    keywordsFlow (Dynamics)
    keywordsChannels (Hydraulic engineering)
    keywordsManufacturing
    keywordsPlasma desorption mass spectrometry
    keywordsMicrofluidics
    keywordsGradients
    keywordsMicrochannels
    keywordsDesign
    keywordsDiffusion (Physics)
    keywordsComputer simulation
    keywordsMicroelectromechanical systems AND Modeling
    treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian