    Transcatheter Aortic Valve Deployment: Interactions Between Native Leaflets and Coronary Ostia

    Source: Journal of Medical Devices:;2009:;volume( 003 ):;issue: 002::page 27530
    Author:
    J. L. Quill
    ,
    A. G. Geeslin
    ,
    P. A. Iaizzo
    DOI: 10.1115/1.3147386
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: During the delivery of a transcatheter aortic valve, the native leaflets are pressed toward the vessel wall when the stented valve is deployed, but the proximity of the native leaflets to the coronary ostia following deployment is not fully understood. Fluoroscopic (F) and endoscopic (E) video footage was gathered from isolated human hearts (n=3). Balloon valvuloplasty (BAV) was performed with a non-compliant balloon, followed by contrast injection into the coronary ostia. Images (F) captured the perpendicular distance from the balloon to the ostia (ostium depth). A nitinol stent was delivered to the aortic position trans-apically. Images (E) measured the distance between the native aortic leaflet and the lowest point of the coronary ostium (ostium height). Additionally, cadaveric hearts (n=23) underwent extensive anatomical analyses using a 3D digitizing arm in addition to the described procedures. BAV in perfusion fixed hearts gave left and right ostium depths of 5.28±1.49 and 5.34±1.85. Images (E) from the perfusion fixed human hearts showed left and right ostium heights of 3.2±2.9 mm and 4.3±2.4, respectively. 2 of the 23 perfusion fixed human hearts studied had negative ostia heights, but the effect on coronary flow is not known.
    • Download: (35.62Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Transcatheter Aortic Valve Deployment: Interactions Between Native Leaflets and Coronary Ostia

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/141604
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorJ. L. Quill
    contributor authorA. G. Geeslin
    contributor authorP. A. Iaizzo
    date accessioned2017-05-09T00:34:44Z
    date available2017-05-09T00:34:44Z
    date copyrightJune, 2009
    date issued2009
    identifier issn1932-6181
    identifier otherJMDOA4-28002#027530_2.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/141604
    description abstractDuring the delivery of a transcatheter aortic valve, the native leaflets are pressed toward the vessel wall when the stented valve is deployed, but the proximity of the native leaflets to the coronary ostia following deployment is not fully understood. Fluoroscopic (F) and endoscopic (E) video footage was gathered from isolated human hearts (n=3). Balloon valvuloplasty (BAV) was performed with a non-compliant balloon, followed by contrast injection into the coronary ostia. Images (F) captured the perpendicular distance from the balloon to the ostia (ostium depth). A nitinol stent was delivered to the aortic position trans-apically. Images (E) measured the distance between the native aortic leaflet and the lowest point of the coronary ostium (ostium height). Additionally, cadaveric hearts (n=23) underwent extensive anatomical analyses using a 3D digitizing arm in addition to the described procedures. BAV in perfusion fixed hearts gave left and right ostium depths of 5.28±1.49 and 5.34±1.85. Images (E) from the perfusion fixed human hearts showed left and right ostium heights of 3.2±2.9 mm and 4.3±2.4, respectively. 2 of the 23 perfusion fixed human hearts studied had negative ostia heights, but the effect on coronary flow is not known.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTranscatheter Aortic Valve Deployment: Interactions Between Native Leaflets and Coronary Ostia
    typeJournal Paper
    journal volume3
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.3147386
    journal fristpage27530
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2009:;volume( 003 ):;issue: 002
    contenttypeFulltext