Show simple item record

contributor authorDaniel F. Kacher
contributor authorJoseph R. Roebuck
contributor authorSimon P. DiMaio
contributor authorJean-Sébastien Plante
contributor authorKenjiro Tadakuma
contributor authorSteven Dubowsky
contributor authorLauren M. DeVita
contributor authorFerenc A. Jolesz
date accessioned2017-05-09T00:34:40Z
date available2017-05-09T00:34:40Z
date copyrightSeptember, 2009
date issued2009
identifier issn1932-6181
identifier otherJMDOA4-28006#031005_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/141535
description abstractA parallel manipulator concept using bistable polymer actuators has been developed to perform prostate cancer biopsy, and deliver therapy within the bore of a magnetic resonance imaging (MRI) scanner. The dielectric elastomer actuators (DEAs) used in this manipulator concept are promising for MRI-compatible robotics because they do not interfere with the high magnetic fields of MRI while having good mechanical performance and being low cost. In the past, these actuators have been plagued by robustness problems when used in a continuous manner. Recent studies show that reliability significantly improves when DEAs are used in a bistable manner, as proposed here. This paper investigates the potential of the proposed manipulator concept by evaluating the positioning accuracy and MRI compatibility of a laboratory prototype, developed for clinically relevant design criteria. An analytical model of the manipulator kinematics is presented. Analytical and experimental results validate that the proposed technology can provide an accurate needle placement required to perform prostate cancer treatments. The prototype’s MRI compatibility is validated in a 3 T clinical MRI scanner. The parallel manipulator concept using bistable polymer actuators is shown to be a viable approach to perform MRI-guided needle insertions for prostate cancer biopsy and therapy.
publisherThe American Society of Mechanical Engineers (ASME)
titleAn MRI-Compatible Needle Manipulator Concept Based on Elastically Averaged Dielectric Elastomer Actuators for Prostate Cancer Treatment: An Accuracy and MR-Compatibility Evaluation in Phantoms
typeJournal Paper
journal volume3
journal issue3
journal titleJournal of Medical Devices
identifier doi10.1115/1.3191729
journal fristpage31005
identifier eissn1932-619X
treeJournal of Medical Devices:;2009:;volume( 003 ):;issue: 003
contenttypeFulltext