    Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurized Water Reactor

    Source: Journal of Engineering for Gas Turbines and Power:;2009:;volume( 131 ):;issue: 002::page 22905
    Author:
    Christophe Vallée
    ,
    Deendarlianto
    ,
    Matthias Beyer
    ,
    Dirk Lucas
    ,
    Helmar Carl
    DOI: 10.1115/1.3043816
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Different scenarios of small break loss of coolant accident for pressurized water reactors (PWRs) lead to the reflux-condenser mode in which steam enters the hot leg from the reactor pressure vessel (RPV) and condenses in the steam generator. A limitation of the condensate backflow toward the RPV by the steam flowing in counter current could affect the core cooling and must be prevented. The simulation of counter-current flow limitation conditions, which is dominated by 3D effects, requires the use of a computational fluid dynamics (CFD) approach. These numerical methods are not yet mature, so dedicated experimental data are needed for validation purposes. In order to investigate the two-phase flow behavior in a complex reactor-typical geometry and to supply suitable data for CFD code validation, the “hot leg model” was built at Forschungszentrum Dresden-Rossendorf (FZD). This setup is devoted to optical measurement techniques, and therefore, a flat test-section design was chosen with a width of 50 mm. The test section outlines represent the hot leg of a German Konvoi PWR at a scale of 1:3 (i.e., 250 mm channel height). The test section is mounted between two separators, one simulating the RPV and the other is connected to the steam generator inlet chamber. The hot leg model is operated under pressure equilibrium in the pressure vessel of the TOPFLOW facility of FZD. The air/water experiments presented in this article focus on the flow structure observed in the region of the riser and of the steam generator inlet chamber at room temperature and pressures up to 3 bar. The performed high-speed observations show the evolution of the stratified interface and the distribution of the two-phase mixture (droplets and bubbles). The counter-current flow limitation was quantified using the variation in the water levels measured in the separators. A confrontation with the images indicates that the initiation of flooding coincides with the reversal of the flow in the horizontal part of the hot leg. Afterward, bigger waves are generated, which develop to slugs. Furthermore, the flooding points obtained from the experiments were compared with empirical correlations available in literature. A good overall agreement was obtained, while the zero penetration was found at lower values of the gaseous Wallis parameter compared with previous work. This deviation can be attributed to the rectangular cross section of the hot leg model.
    keyword(s): Flow (Dynamics) , Floods , Water , Pressure AND Pressurized water reactors ,
    • Download: (665.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurized Water Reactor

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/140522
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorChristophe Vallée
    contributor authorDeendarlianto
    contributor authorMatthias Beyer
    contributor authorDirk Lucas
    contributor authorHelmar Carl
    date accessioned2017-05-09T00:32:46Z
    date available2017-05-09T00:32:46Z
    date copyrightMarch, 2009
    date issued2009
    identifier issn1528-8919
    identifier otherJETPEZ-27059#022905_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/140522
    description abstractDifferent scenarios of small break loss of coolant accident for pressurized water reactors (PWRs) lead to the reflux-condenser mode in which steam enters the hot leg from the reactor pressure vessel (RPV) and condenses in the steam generator. A limitation of the condensate backflow toward the RPV by the steam flowing in counter current could affect the core cooling and must be prevented. The simulation of counter-current flow limitation conditions, which is dominated by 3D effects, requires the use of a computational fluid dynamics (CFD) approach. These numerical methods are not yet mature, so dedicated experimental data are needed for validation purposes. In order to investigate the two-phase flow behavior in a complex reactor-typical geometry and to supply suitable data for CFD code validation, the “hot leg model” was built at Forschungszentrum Dresden-Rossendorf (FZD). This setup is devoted to optical measurement techniques, and therefore, a flat test-section design was chosen with a width of 50 mm. The test section outlines represent the hot leg of a German Konvoi PWR at a scale of 1:3 (i.e., 250 mm channel height). The test section is mounted between two separators, one simulating the RPV and the other is connected to the steam generator inlet chamber. The hot leg model is operated under pressure equilibrium in the pressure vessel of the TOPFLOW facility of FZD. The air/water experiments presented in this article focus on the flow structure observed in the region of the riser and of the steam generator inlet chamber at room temperature and pressures up to 3 bar. The performed high-speed observations show the evolution of the stratified interface and the distribution of the two-phase mixture (droplets and bubbles). The counter-current flow limitation was quantified using the variation in the water levels measured in the separators. A confrontation with the images indicates that the initiation of flooding coincides with the reversal of the flow in the horizontal part of the hot leg. Afterward, bigger waves are generated, which develop to slugs. Furthermore, the flooding points obtained from the experiments were compared with empirical correlations available in literature. A good overall agreement was obtained, while the zero penetration was found at lower values of the gaseous Wallis parameter compared with previous work. This deviation can be attributed to the rectangular cross section of the hot leg model.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAir/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurized Water Reactor
    typeJournal Paper
    journal volume131
    journal issue2
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.3043816
    journal fristpage22905
    identifier eissn0742-4795
    keywordsFlow (Dynamics)
    keywordsFloods
    keywordsWater
    keywordsPressure AND Pressurized water reactors
    treeJournal of Engineering for Gas Turbines and Power:;2009:;volume( 131 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian