Experimental Testing of Gerotor and Scroll Expanders Used in, and Energetic and Exergetic Modeling of, an Organic Rankine CycleSource: Journal of Energy Resources Technology:;2009:;volume( 131 ):;issue: 001::page 12201Author:James A. Mathias
,
Jon R. Johnston
,
Jiming Cao
,
Douglas K. Priedeman
,
Richard N. Christensen
DOI: 10.1115/1.3066345Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: This paper presents the experimental testing of relatively cost-effective expanders in an organic Rankine cycle (ORC) to produce power from low-grade energy. Gerotor and scroll expanders were the two types of expanders tested to determine their applicability in producing power from low-grade energy. The results of the experimental testing showed that both types of expanders were good candidates to be used in an ORC. The gerotor and scroll expanders tested produced 2.07 kW and 2.96 kW, and had isentropic efficiencies of 0.85 and 0.83, respectively. Also the paper presents results of an analytical model produced that predicted improved cycle efficiency with certain changes. One change was the flow rate of the working fluid in the cycle was properly matched with the inlet pocket volume and rotational speed of the expander. Also, the volumetric expansion ratio of the expander was matched to the specific volume ratio of the working fluid (R-123) across the expander. The model incorporated the efficiencies of the expanders and pump obtained during experimental testing, and combined two expanders in series to match the specific volume ratio of the working fluid. The model determined the power produced by the expanders, and subtracted the power required by the working fluid pump and the condenser fan. From that, the model calculated the net power produced to be 6271 W and the overall energy efficiency of the cycle to be 7.7%. When the ORC was simulated to be integrated with the exhaust of a stationary engine, the exergetic efficiency, exergy destroyed, and reduction in diesel fuel while still producing the same amount of power during 2500 h of operation were 22.1%, 22,169 W, and 4,012 L (1060 U.S. gal), respectively. Consequently, the model presents a very realistic design based on results from experimental testing to cost-effectively use low-grade energy.
keyword(s): Flow (Dynamics) , Temperature , Fluids , Engines , Exergy , Boilers , Heat exchangers , Modeling , Pumps , Testing , Condensers (steam plant) , Cycles , Exhaust systems , Rankine cycle , Pressure AND Water ,
|
Collections
Show full item record
| contributor author | James A. Mathias | |
| contributor author | Jon R. Johnston | |
| contributor author | Jiming Cao | |
| contributor author | Douglas K. Priedeman | |
| contributor author | Richard N. Christensen | |
| date accessioned | 2017-05-09T00:32:27Z | |
| date available | 2017-05-09T00:32:27Z | |
| date copyright | March, 2009 | |
| date issued | 2009 | |
| identifier issn | 0195-0738 | |
| identifier other | JERTD2-26559#012201_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/140369 | |
| description abstract | This paper presents the experimental testing of relatively cost-effective expanders in an organic Rankine cycle (ORC) to produce power from low-grade energy. Gerotor and scroll expanders were the two types of expanders tested to determine their applicability in producing power from low-grade energy. The results of the experimental testing showed that both types of expanders were good candidates to be used in an ORC. The gerotor and scroll expanders tested produced 2.07 kW and 2.96 kW, and had isentropic efficiencies of 0.85 and 0.83, respectively. Also the paper presents results of an analytical model produced that predicted improved cycle efficiency with certain changes. One change was the flow rate of the working fluid in the cycle was properly matched with the inlet pocket volume and rotational speed of the expander. Also, the volumetric expansion ratio of the expander was matched to the specific volume ratio of the working fluid (R-123) across the expander. The model incorporated the efficiencies of the expanders and pump obtained during experimental testing, and combined two expanders in series to match the specific volume ratio of the working fluid. The model determined the power produced by the expanders, and subtracted the power required by the working fluid pump and the condenser fan. From that, the model calculated the net power produced to be 6271 W and the overall energy efficiency of the cycle to be 7.7%. When the ORC was simulated to be integrated with the exhaust of a stationary engine, the exergetic efficiency, exergy destroyed, and reduction in diesel fuel while still producing the same amount of power during 2500 h of operation were 22.1%, 22,169 W, and 4,012 L (1060 U.S. gal), respectively. Consequently, the model presents a very realistic design based on results from experimental testing to cost-effectively use low-grade energy. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Experimental Testing of Gerotor and Scroll Expanders Used in, and Energetic and Exergetic Modeling of, an Organic Rankine Cycle | |
| type | Journal Paper | |
| journal volume | 131 | |
| journal issue | 1 | |
| journal title | Journal of Energy Resources Technology | |
| identifier doi | 10.1115/1.3066345 | |
| journal fristpage | 12201 | |
| identifier eissn | 1528-8994 | |
| keywords | Flow (Dynamics) | |
| keywords | Temperature | |
| keywords | Fluids | |
| keywords | Engines | |
| keywords | Exergy | |
| keywords | Boilers | |
| keywords | Heat exchangers | |
| keywords | Modeling | |
| keywords | Pumps | |
| keywords | Testing | |
| keywords | Condensers (steam plant) | |
| keywords | Cycles | |
| keywords | Exhaust systems | |
| keywords | Rankine cycle | |
| keywords | Pressure AND Water | |
| tree | Journal of Energy Resources Technology:;2009:;volume( 131 ):;issue: 001 | |
| contenttype | Fulltext |