Energy Conservation Opportunity in Boiler SystemsSource: Journal of Energy Resources Technology:;2009:;volume( 131 ):;issue: 003::page 32401DOI: 10.1115/1.3185440Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: In this study, “energy efficiency” study has been performed for a natural gas fuelled boiler, operating at 42,000 kPa pressure and 713.15 K temperature, with a nominal capacity of 33.33 kg/s steam. Within this frame, temperature, pressure, velocity, and gas analysis measurements have been made, and energy, mass balances, and exergy analysis have been formed. Then, the efficiency of boiler, potential energy saving options and savings quantities, investment costs, and payback period for normal operating conditions have been calculated from the energy and mass balances. Implementation cost is required only for reducing air leakages in the rotary type air heater and surface thermal losses. The investment cost for reducing air leakage in the rotary type air heater to the acceptable limits (10%) is 600,000 USD. Under these circumstances, the payback period of this investment cost is about fifteen months.
keyword(s): Fuels , Potential energy , Boilers , Pressure vessel systems , Steam , Leakage , Measurement , Temperature , Stress , Exergy analysis AND Natural gas ,
|
Collections
Show full item record
| contributor author | Durmus Kaya | |
| contributor author | Muharrem Eyidogan | |
| date accessioned | 2017-05-09T00:32:25Z | |
| date available | 2017-05-09T00:32:25Z | |
| date copyright | September, 2009 | |
| date issued | 2009 | |
| identifier issn | 0195-0738 | |
| identifier other | JERTD2-26563#032401_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/140352 | |
| description abstract | In this study, “energy efficiency” study has been performed for a natural gas fuelled boiler, operating at 42,000 kPa pressure and 713.15 K temperature, with a nominal capacity of 33.33 kg/s steam. Within this frame, temperature, pressure, velocity, and gas analysis measurements have been made, and energy, mass balances, and exergy analysis have been formed. Then, the efficiency of boiler, potential energy saving options and savings quantities, investment costs, and payback period for normal operating conditions have been calculated from the energy and mass balances. Implementation cost is required only for reducing air leakages in the rotary type air heater and surface thermal losses. The investment cost for reducing air leakage in the rotary type air heater to the acceptable limits (10%) is 600,000 USD. Under these circumstances, the payback period of this investment cost is about fifteen months. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Energy Conservation Opportunity in Boiler Systems | |
| type | Journal Paper | |
| journal volume | 131 | |
| journal issue | 3 | |
| journal title | Journal of Energy Resources Technology | |
| identifier doi | 10.1115/1.3185440 | |
| journal fristpage | 32401 | |
| identifier eissn | 1528-8994 | |
| keywords | Fuels | |
| keywords | Potential energy | |
| keywords | Boilers | |
| keywords | Pressure vessel systems | |
| keywords | Steam | |
| keywords | Leakage | |
| keywords | Measurement | |
| keywords | Temperature | |
| keywords | Stress | |
| keywords | Exergy analysis AND Natural gas | |
| tree | Journal of Energy Resources Technology:;2009:;volume( 131 ):;issue: 003 | |
| contenttype | Fulltext |