YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Cortical Screw Purchase in Synthetic and Human Femurs

    Source: Journal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 009::page 94503
    Author:
    Rad Zdero
    ,
    Khaled Elfallah
    ,
    Michael Olsen
    ,
    Emil H. Schemitsch
    DOI: 10.1115/1.3194755
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Biomechanical investigations of orthopedic fracture fixation constructs increasingly use analogs like the third and fourth generation composite femurs. However, no study has directly compared cortical screw purchase between these surrogates and human femurs, which was the present aim. Synthetic and human femurs had bicortical orthopedic screws (diameter=3.5 mm and length=50 mm) inserted in three locations along the anterior length. The screws were extracted to obtain pullout force, shear stress, and energy-to-pullout. The four study groups (n=6 femurs each) assessed were the fourth generation composite femur with both 16 mm and 20 mm diameter canals, the third generation composite femur with a 16 mm canal, and the human femur. For a given femur type, there was no statistical difference between the proximal, center, or distal screw sites for virtually all comparisons. The fourth generation composite femur with a 20 mm canal was closest to the human femur for the outcome measures considered. Synthetic femurs showed a range of average measures (2948.54–5286.30 N, 27.30–35.60 MPa, and 3.63–9.95 J) above that for human femurs (1645.92–3084.95 N, 17.86–24.64 MPa, and 1.82–3.27 J). Shear stress and energy-to-pullout were useful supplemental evaluators of screw purchase, since they account for material properties and screw motion. Although synthetic femurs approximated human femurs with respect to screw extraction behavior, ongoing research is required to definitively determine which type of synthetic femur most closely resembles normal, osteopenic, or osteoporotic human bone at the screw-bone interface.
    keyword(s): Screws , Bone , Stress , Force AND Shear (Mechanics) ,
    • Download: (369.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Cortical Screw Purchase in Synthetic and Human Femurs

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/139865
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorRad Zdero
    contributor authorKhaled Elfallah
    contributor authorMichael Olsen
    contributor authorEmil H. Schemitsch
    date accessioned2017-05-09T00:31:32Z
    date available2017-05-09T00:31:32Z
    date copyrightSeptember, 2009
    date issued2009
    identifier issn0148-0731
    identifier otherJBENDY-27031#094503_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139865
    description abstractBiomechanical investigations of orthopedic fracture fixation constructs increasingly use analogs like the third and fourth generation composite femurs. However, no study has directly compared cortical screw purchase between these surrogates and human femurs, which was the present aim. Synthetic and human femurs had bicortical orthopedic screws (diameter=3.5 mm and length=50 mm) inserted in three locations along the anterior length. The screws were extracted to obtain pullout force, shear stress, and energy-to-pullout. The four study groups (n=6 femurs each) assessed were the fourth generation composite femur with both 16 mm and 20 mm diameter canals, the third generation composite femur with a 16 mm canal, and the human femur. For a given femur type, there was no statistical difference between the proximal, center, or distal screw sites for virtually all comparisons. The fourth generation composite femur with a 20 mm canal was closest to the human femur for the outcome measures considered. Synthetic femurs showed a range of average measures (2948.54–5286.30 N, 27.30–35.60 MPa, and 3.63–9.95 J) above that for human femurs (1645.92–3084.95 N, 17.86–24.64 MPa, and 1.82–3.27 J). Shear stress and energy-to-pullout were useful supplemental evaluators of screw purchase, since they account for material properties and screw motion. Although synthetic femurs approximated human femurs with respect to screw extraction behavior, ongoing research is required to definitively determine which type of synthetic femur most closely resembles normal, osteopenic, or osteoporotic human bone at the screw-bone interface.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCortical Screw Purchase in Synthetic and Human Femurs
    typeJournal Paper
    journal volume131
    journal issue9
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.3194755
    journal fristpage94503
    identifier eissn1528-8951
    keywordsScrews
    keywordsBone
    keywordsStress
    keywordsForce AND Shear (Mechanics)
    treeJournal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian