    An Ultrasound Probe Holder for Image-Guided Surgery

    Source: Journal of Medical Devices:;2008:;volume( 002 ):;issue: 002::page 21002
    Author:
    Basem Fayez Yousef
    ,
    Rajni V. Patel
    ,
    Mehrdad Moallem
    DOI: 10.1115/1.2912817
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Automating image-guided therapy and registering a medical image to a patient require knowledge of the locations of both the medical image source (e.g., ultrasound) and the surgical tool with respect to a global coordinate system that is known relative to the patient. Also, sturdiness of the medical instrumentations is essential. A novel compact stabilizer-tracker integrated assembly is designed to serve as a holder that can be used to support, manipulate in six degrees-of-freedom, and firmly lock-in-place ultrasound imaging probes and other instruments for use in image-guided surgery as well as to provide the position and orientation of the probe in 3D space with respect to a known reference origin. The stabilizer’s configuration allows a clinician to easily manipulate an ultrasound probe in 3D space, and demonstrate improved sturdiness when locked. A reliable validation technique using forward kinematics was used to evaluate the performance of the holder. Performance tests show that the tracker assembly can acquire the position and orientation of the ultrasound probe with an average displacement accuracy of 0.66mm and roll, pitch, and yaw angular accuracies of 0.24deg, 0.38deg, and 0.19deg, respectively. The improved sturdiness demonstrated by the compact-sized stabilizer and the high accuracy of the tracking mechanism make the integrated holder mechanism well suited for use in image-guided robot-assisted brachytherapy. It is anticipated that this will lead to improvement in accuracy and clinical outcomes for the procedure. The novel tracker can also be used to acquire the positions and orientations of other passive mechanisms of complex designs.
    • Download: (632.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      An Ultrasound Probe Holder for Image-Guided Surgery

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/139082
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorBasem Fayez Yousef
    contributor authorRajni V. Patel
    contributor authorMehrdad Moallem
    date accessioned2017-05-09T00:30:02Z
    date available2017-05-09T00:30:02Z
    date copyrightJune, 2008
    date issued2008
    identifier issn1932-6181
    identifier otherJMDOA4-27991#021002_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139082
    description abstractAutomating image-guided therapy and registering a medical image to a patient require knowledge of the locations of both the medical image source (e.g., ultrasound) and the surgical tool with respect to a global coordinate system that is known relative to the patient. Also, sturdiness of the medical instrumentations is essential. A novel compact stabilizer-tracker integrated assembly is designed to serve as a holder that can be used to support, manipulate in six degrees-of-freedom, and firmly lock-in-place ultrasound imaging probes and other instruments for use in image-guided surgery as well as to provide the position and orientation of the probe in 3D space with respect to a known reference origin. The stabilizer’s configuration allows a clinician to easily manipulate an ultrasound probe in 3D space, and demonstrate improved sturdiness when locked. A reliable validation technique using forward kinematics was used to evaluate the performance of the holder. Performance tests show that the tracker assembly can acquire the position and orientation of the ultrasound probe with an average displacement accuracy of 0.66mm and roll, pitch, and yaw angular accuracies of 0.24deg, 0.38deg, and 0.19deg, respectively. The improved sturdiness demonstrated by the compact-sized stabilizer and the high accuracy of the tracking mechanism make the integrated holder mechanism well suited for use in image-guided robot-assisted brachytherapy. It is anticipated that this will lead to improvement in accuracy and clinical outcomes for the procedure. The novel tracker can also be used to acquire the positions and orientations of other passive mechanisms of complex designs.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAn Ultrasound Probe Holder for Image-Guided Surgery
    typeJournal Paper
    journal volume2
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.2912817
    journal fristpage21002
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2008:;volume( 002 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian