| contributor author | Daniel Walczyk | |
| contributor author | Nathaniel Ordway | |
| contributor author | Kenneth Mann | |
| contributor author | William Ziomek | |
| date accessioned | 2017-05-09T00:29:57Z | |
| date available | 2017-05-09T00:29:57Z | |
| date copyright | June, 2008 | |
| date issued | 2008 | |
| identifier issn | 1932-6181 | |
| identifier other | JMDOA4-27991#027528_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/139035 | |
| description abstract | A weight bearing indicator (WBI) has been developed and is undergoing clinical trials and commercialization. The most recent version of the device includes load range indication ability. The WBI is installed in a patient’s medical appliance (e.g. cam walker boot, surgical shoe) and allows patients recovering from lower extremity injuries to self monitor their rehabilitation. It is a simple and inexpensive mechanical device that utilizes the reversible buckling phenomena of a snap dome to provide a tactile ‘click’ and an audible ‘snap’ when a specified ground load on the bottom of a patient’s foot, which has been prescribed by an orthopedist or podiatrist as the partial weight bearing (PWB) upper limit, has been met or exceeded. A clinical study involving 20 subjects showed that PWB compliance improved when comparing the WBI device to standard of care approaches such as verbal instruction and the weight scale method. Specifically, PWB compliance improved from 58% and 45% body weight (BW) for verbal instruction and weight scale method, respectively, to 33% BW for the WBI device. In addition, PWB compliance using the WBI device was not dependent on subject weight like the standard of care approaches. Sometimes patients are instructed not only to avoid exceeding an upper load limit, but also to maintain their limb load above a lower limit as well. A newer version of the WBI has been developed that provides two distinct clicks to a patient corresponding to an upper and lower load limits. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Progress on Clinical Trials and Product Development of a Simple, Inexpensive Feedback Device for Patients Requiring Partial Weight Bearing | |
| type | Journal Paper | |
| journal volume | 2 | |
| journal issue | 2 | |
| journal title | Journal of Medical Devices | |
| identifier doi | 10.1115/1.2936203 | |
| journal fristpage | 27528 | |
| identifier eissn | 1932-619X | |
| tree | Journal of Medical Devices:;2008:;volume( 002 ):;issue: 002 | |
| contenttype | Fulltext | |