    Deviations in Predicted Condenser Performance for Power Plants Using HEI Correction Factors: A Case Study

    Source: Journal of Engineering for Gas Turbines and Power:;2008:;volume( 130 ):;issue: 002::page 23003
    Author:
    Komandur S. Sunder Raj
    DOI: 10.1115/1.2795779
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The Heat Exchange Institute (HEI) Standards for Steam Surface Condensers are used to design and predict the performance of condensers for power plant applications. Since their inception, the Standards have undergone numerous changes to incorporate technological advances and revisions to various factors based on testing and operating experiences. Admiralty and copper-nickel (CuNi) tubes were very popular until the 1970s. Subsequently, increasing concerns with the use of copper-based alloys in nuclear power plants as well as other factors led to specification and use of stainless steel (SS) and titanium. The first condenser designed with titanium tubes was put into service in 1977. In 1978, the HEI published the seventh edition of the HEI Standards for Steam Surface Condensers. The eighth edition was issued in 1984 followed by Addendum 1 in 1989. The ninth edition was issued in 1995 and Addendum 1 to the ninth edition was published in 2002. Notable differences between the ninth and seventh editions include higher circulating water inlet temperature correction factors below 70.0°F; for Admiralty, higher tube material and gauge correction factors for tube wall gauge below 16 Birmingham wire gauge (BWG) and lower values above 20 BWG; for 90∕10 CuNi and 304 SS, higher tube material and gauge correction factors for tube wall gauge between 12 BWG and 24 BWG; and for titanium, higher tube material and gauge correction factors for tube wall gauge above 18 BWG. Depending upon the tube diameter, material, wall gauge, and the correction factors used for a specific condenser application and its operating range, there could be substantial deviations in predicted condenser performance and associated impact on output. Using a case study, this paper examines the use of the correction factors from the seventh and ninth editions in power plant condenser performance predictions. It provides recommendations for developing proper benchmarks and for ensuring optimum condenser performance.
    keyword(s): Heat , Temperature , Power stations , Condensers (steam plant) , Water , Titanium , Design AND Generators ,
    • Download: (501.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Deviations in Predicted Condenser Performance for Power Plants Using HEI Correction Factors: A Case Study

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/137993
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorKomandur S. Sunder Raj
    date accessioned2017-05-09T00:28:03Z
    date available2017-05-09T00:28:03Z
    date copyrightMarch, 2008
    date issued2008
    identifier issn1528-8919
    identifier otherJETPEZ-27001#023003_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/137993
    description abstractThe Heat Exchange Institute (HEI) Standards for Steam Surface Condensers are used to design and predict the performance of condensers for power plant applications. Since their inception, the Standards have undergone numerous changes to incorporate technological advances and revisions to various factors based on testing and operating experiences. Admiralty and copper-nickel (CuNi) tubes were very popular until the 1970s. Subsequently, increasing concerns with the use of copper-based alloys in nuclear power plants as well as other factors led to specification and use of stainless steel (SS) and titanium. The first condenser designed with titanium tubes was put into service in 1977. In 1978, the HEI published the seventh edition of the HEI Standards for Steam Surface Condensers. The eighth edition was issued in 1984 followed by Addendum 1 in 1989. The ninth edition was issued in 1995 and Addendum 1 to the ninth edition was published in 2002. Notable differences between the ninth and seventh editions include higher circulating water inlet temperature correction factors below 70.0°F; for Admiralty, higher tube material and gauge correction factors for tube wall gauge below 16 Birmingham wire gauge (BWG) and lower values above 20 BWG; for 90∕10 CuNi and 304 SS, higher tube material and gauge correction factors for tube wall gauge between 12 BWG and 24 BWG; and for titanium, higher tube material and gauge correction factors for tube wall gauge above 18 BWG. Depending upon the tube diameter, material, wall gauge, and the correction factors used for a specific condenser application and its operating range, there could be substantial deviations in predicted condenser performance and associated impact on output. Using a case study, this paper examines the use of the correction factors from the seventh and ninth editions in power plant condenser performance predictions. It provides recommendations for developing proper benchmarks and for ensuring optimum condenser performance.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDeviations in Predicted Condenser Performance for Power Plants Using HEI Correction Factors: A Case Study
    typeJournal Paper
    journal volume130
    journal issue2
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.2795779
    journal fristpage23003
    identifier eissn0742-4795
    keywordsHeat
    keywordsTemperature
    keywordsPower stations
    keywordsCondensers (steam plant)
    keywordsWater
    keywordsTitanium
    keywordsDesign AND Generators
    treeJournal of Engineering for Gas Turbines and Power:;2008:;volume( 130 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian