    Derivation of Diagnostic Requirements for a Distributed UAV Turbofan Engine Control System

    Source: Journal of Engineering for Gas Turbines and Power:;2008:;volume( 130 ):;issue: 002::page 21602
    Author:
    Olof Hannius
    ,
    Johan Karlsson
    ,
    Dan Ring
    DOI: 10.1115/1.2795776
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper presents a method for deriving requirements for the efficiency of diagnostic functions in distributed electronic turbofan engine control systems. Distributed engine control systems consist of sensor, actuator, and control unit nodes that exchange data over a communication network. The method is applicable to engine control systems that are partially redundant. Traditionally, turbofan engine control systems use dual channel solutions in which all units are duplicated. Our method is intended for analyzing the diagnostic requirements for systems in which a subset of the sensors and the actuators is nonredundant. Such systems rely on intelligent monitoring and analytical redundancy to detect and tolerate failures in the nonredundant units. These techniques cannot provide perfect diagnostic coverage and, hence, our method focuses on analyzing the impact of nonperfect diagnostic coverage on the reliability and safety of distributed engine control systems. The method is based on a probabilistic analysis that combines fault trees and Markov chains. The input parameters for these models include failure rates as well as several coverage factors that characterize the performance of the diagnostic functions. Since the use of intelligent monitoring can cause false alarms, i.e., an error is falsely indicated by a diagnostic function, the parameters also include a false alarm rate. The method was used to derive the diagnostic requirements for a hypothetical unmanned aerial vehicle engine control system. Given the requirement that an engine failure due to the control system is not allowed to occur more than ten times per million hours, the diagnostic functions in a node must achieve 99% error coverage for transient faults and 90–99% error coverage for permanent faults. The system-level diagnosis must achieve 90–95% detection coverage for node failures, which are not detected by the nodes themselves. These results are based on the assumption that transient faults are 100 times more frequent than permanent faults. It is important to have a method for deriving probabilistic requirements on diagnostic functions for engine control systems that rely on analytical redundancy as a means to reduce the hardware redundancy. The proposed method allows us to do this using an existing tool (FAULTTREE+ ) for safety and reliability analysis.
    keyword(s): Control systems , Engines , Errors , Failure , Tree (Data structure) , Unmanned aerial vehicles , Chain , Probability , Turbofans , Safety , Sensors AND Hardware ,
    • Download: (859.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Derivation of Diagnostic Requirements for a Distributed UAV Turbofan Engine Control System

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/137969
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorOlof Hannius
    contributor authorJohan Karlsson
    contributor authorDan Ring
    date accessioned2017-05-09T00:27:57Z
    date available2017-05-09T00:27:57Z
    date copyrightMarch, 2008
    date issued2008
    identifier issn1528-8919
    identifier otherJETPEZ-27001#021602_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/137969
    description abstractThis paper presents a method for deriving requirements for the efficiency of diagnostic functions in distributed electronic turbofan engine control systems. Distributed engine control systems consist of sensor, actuator, and control unit nodes that exchange data over a communication network. The method is applicable to engine control systems that are partially redundant. Traditionally, turbofan engine control systems use dual channel solutions in which all units are duplicated. Our method is intended for analyzing the diagnostic requirements for systems in which a subset of the sensors and the actuators is nonredundant. Such systems rely on intelligent monitoring and analytical redundancy to detect and tolerate failures in the nonredundant units. These techniques cannot provide perfect diagnostic coverage and, hence, our method focuses on analyzing the impact of nonperfect diagnostic coverage on the reliability and safety of distributed engine control systems. The method is based on a probabilistic analysis that combines fault trees and Markov chains. The input parameters for these models include failure rates as well as several coverage factors that characterize the performance of the diagnostic functions. Since the use of intelligent monitoring can cause false alarms, i.e., an error is falsely indicated by a diagnostic function, the parameters also include a false alarm rate. The method was used to derive the diagnostic requirements for a hypothetical unmanned aerial vehicle engine control system. Given the requirement that an engine failure due to the control system is not allowed to occur more than ten times per million hours, the diagnostic functions in a node must achieve 99% error coverage for transient faults and 90–99% error coverage for permanent faults. The system-level diagnosis must achieve 90–95% detection coverage for node failures, which are not detected by the nodes themselves. These results are based on the assumption that transient faults are 100 times more frequent than permanent faults. It is important to have a method for deriving probabilistic requirements on diagnostic functions for engine control systems that rely on analytical redundancy as a means to reduce the hardware redundancy. The proposed method allows us to do this using an existing tool (FAULTTREE+ ) for safety and reliability analysis.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDerivation of Diagnostic Requirements for a Distributed UAV Turbofan Engine Control System
    typeJournal Paper
    journal volume130
    journal issue2
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.2795776
    journal fristpage21602
    identifier eissn0742-4795
    keywordsControl systems
    keywordsEngines
    keywordsErrors
    keywordsFailure
    keywordsTree (Data structure)
    keywordsUnmanned aerial vehicles
    keywordsChain
    keywordsProbability
    keywordsTurbofans
    keywordsSafety
    keywordsSensors AND Hardware
    treeJournal of Engineering for Gas Turbines and Power:;2008:;volume( 130 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian