YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    A Musculoskeletal Model of the Equine Forelimb for Determining Surface Stresses and Strains in the Humerus—Part I. Mathematical Modeling

    Source: Journal of Biomechanical Engineering:;2008:;volume( 130 ):;issue: 004::page 41006
    Author:
    Sarah Pollock
    ,
    M. L. Hull
    ,
    Susan M. Stover
    ,
    Larry D. Galuppo
    DOI: 10.1115/1.2898726
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Knowledge of the forces that act upon the equine humerus while the horse is standing and the resulting strains experienced by the bone is useful for the prevention and treatment of fractures and for assessing the proximolateral aspect of the bone as a site for obtaining autogenous bone graft material. The first objective was to develop a mathematical model to predict the loads on the proximal half of the humerus created by the surrounding musculature and ground reaction forces while the horse is standing. The second objective was to calculate surface bone stresses and strains at three cross sections on the humerus corresponding to the donor site for bone grafts, a site predisposed to stress fracture, and the middle of the diaphysis. A three-dimensional mathematical model employing optimization techniques and asymmetrical beam analysis was used to calculate shoulder muscle forces and surface strains on the proximal and mid-diaphyseal aspects of the humerus. The active shoulder muscles, which included the supraspinatus, infraspinatus, subscapularis, and short head of the deltoid, produced small forces while the horse is standing; all of which were limited to 4.3% of their corresponding maximum voluntary contraction. As a result, the strains calculated at the proximal cross sections of the humerus were small, with maximum compressive strains of −104με at the cranial aspect of the bone graft donor cross section. The middle of the diaphysis experienced larger strain magnitudes with compressive strains at the lateral and the caudal aspects and tensile strains at the medial and cranial aspects (−377με and 258με maximum values, respectively) while the horse is standing. Small strains at the donor bone graft site do not rule out using this location to harvest bone graft tissue, although strains while rising to a standing position during recovery from anesthesia are unknown. At the site common to stress fractures, small strains imply that the stresses seen by this region while the horse is standing, although applied for long periods of time, are not a cause of fracture in this location. Knowing the specific regions of the middle of the diaphysis of the humerus that experience tensile and compressive strains is valuable in determining optimum placement of internal fixation devices for the treatment of complete fractures.
    keyword(s): Force , Stress , Bone , Muscle , Fracture (Process) , Musculoskeletal system AND Cross section (Physics) ,
    • Download: (369.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Musculoskeletal Model of the Equine Forelimb for Determining Surface Stresses and Strains in the Humerus—Part I. Mathematical Modeling

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/137429
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorSarah Pollock
    contributor authorM. L. Hull
    contributor authorSusan M. Stover
    contributor authorLarry D. Galuppo
    date accessioned2017-05-09T00:26:58Z
    date available2017-05-09T00:26:58Z
    date copyrightAugust, 2008
    date issued2008
    identifier issn0148-0731
    identifier otherJBENDY-26817#041006_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/137429
    description abstractKnowledge of the forces that act upon the equine humerus while the horse is standing and the resulting strains experienced by the bone is useful for the prevention and treatment of fractures and for assessing the proximolateral aspect of the bone as a site for obtaining autogenous bone graft material. The first objective was to develop a mathematical model to predict the loads on the proximal half of the humerus created by the surrounding musculature and ground reaction forces while the horse is standing. The second objective was to calculate surface bone stresses and strains at three cross sections on the humerus corresponding to the donor site for bone grafts, a site predisposed to stress fracture, and the middle of the diaphysis. A three-dimensional mathematical model employing optimization techniques and asymmetrical beam analysis was used to calculate shoulder muscle forces and surface strains on the proximal and mid-diaphyseal aspects of the humerus. The active shoulder muscles, which included the supraspinatus, infraspinatus, subscapularis, and short head of the deltoid, produced small forces while the horse is standing; all of which were limited to 4.3% of their corresponding maximum voluntary contraction. As a result, the strains calculated at the proximal cross sections of the humerus were small, with maximum compressive strains of −104με at the cranial aspect of the bone graft donor cross section. The middle of the diaphysis experienced larger strain magnitudes with compressive strains at the lateral and the caudal aspects and tensile strains at the medial and cranial aspects (−377με and 258με maximum values, respectively) while the horse is standing. Small strains at the donor bone graft site do not rule out using this location to harvest bone graft tissue, although strains while rising to a standing position during recovery from anesthesia are unknown. At the site common to stress fractures, small strains imply that the stresses seen by this region while the horse is standing, although applied for long periods of time, are not a cause of fracture in this location. Knowing the specific regions of the middle of the diaphysis of the humerus that experience tensile and compressive strains is valuable in determining optimum placement of internal fixation devices for the treatment of complete fractures.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Musculoskeletal Model of the Equine Forelimb for Determining Surface Stresses and Strains in the Humerus—Part I. Mathematical Modeling
    typeJournal Paper
    journal volume130
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2898726
    journal fristpage41006
    identifier eissn1528-8951
    keywordsForce
    keywordsStress
    keywordsBone
    keywordsMuscle
    keywordsFracture (Process)
    keywordsMusculoskeletal system AND Cross section (Physics)
    treeJournal of Biomechanical Engineering:;2008:;volume( 130 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian