    Sensitivity Analysis of Optimal Building Thermal Mass Control

    Source: Journal of Solar Energy Engineering:;2007:;volume( 129 ):;issue: 004::page 473
    Author:
    Gregor P. Henze
    ,
    Thoi H. Le
    ,
    Anthony R. Florita
    ,
    Clemens Felsmann
    DOI: 10.1115/1.2770755
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In order to avoid high utility demand charges from cooling during the summer and to level a building’s electrical demand profile, precooling of the building’s massive structure can be applied to shift cooling-related thermal loads in response to utility pricing signals. Several previous simulation and experimental studies have shown that proper precooling can attain considerable reduction of operating cost in buildings. This paper systematically evaluates the merits of the passive building thermal capacitance to minimize energy cost for a design day using optimal control. The evaluation is conducted by means of a sensitivity analysis utilizing a dynamic building energy simulation program coupled to a popular technical computing environment. The optimal controller predicts the required extent of precooling (zone temperature set-point depression), depending on the utility rate structure, occupancy and on-peak period duration and onset, internal gains, building mass, occupancy period temperature set-point range, and weather as characterized by diurnal temperature and relative humidity swings. In addition to quantifying the building response, energy consumption, and utility cost, this paper extracts the dominant features of the optimal precooling strategies for each of the investigated cases so that guidelines for near-optimal building thermal mass savings may be developed in the future.
    keyword(s): Stress , Modeling , Optimal control , Energy consumption , Sensitivity analysis , Thermal energy storage , Temperature , Cooling , Simulation AND Structures ,
    • Download: (2.769Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Sensitivity Analysis of Optimal Building Thermal Mass Control

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/136777
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorGregor P. Henze
    contributor authorThoi H. Le
    contributor authorAnthony R. Florita
    contributor authorClemens Felsmann
    date accessioned2017-05-09T00:25:39Z
    date available2017-05-09T00:25:39Z
    date copyrightNovember, 2007
    date issued2007
    identifier issn0199-6231
    identifier otherJSEEDO-28408#473_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/136777
    description abstractIn order to avoid high utility demand charges from cooling during the summer and to level a building’s electrical demand profile, precooling of the building’s massive structure can be applied to shift cooling-related thermal loads in response to utility pricing signals. Several previous simulation and experimental studies have shown that proper precooling can attain considerable reduction of operating cost in buildings. This paper systematically evaluates the merits of the passive building thermal capacitance to minimize energy cost for a design day using optimal control. The evaluation is conducted by means of a sensitivity analysis utilizing a dynamic building energy simulation program coupled to a popular technical computing environment. The optimal controller predicts the required extent of precooling (zone temperature set-point depression), depending on the utility rate structure, occupancy and on-peak period duration and onset, internal gains, building mass, occupancy period temperature set-point range, and weather as characterized by diurnal temperature and relative humidity swings. In addition to quantifying the building response, energy consumption, and utility cost, this paper extracts the dominant features of the optimal precooling strategies for each of the investigated cases so that guidelines for near-optimal building thermal mass savings may be developed in the future.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSensitivity Analysis of Optimal Building Thermal Mass Control
    typeJournal Paper
    journal volume129
    journal issue4
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.2770755
    journal fristpage473
    journal lastpage485
    identifier eissn1528-8986
    keywordsStress
    keywordsModeling
    keywordsOptimal control
    keywordsEnergy consumption
    keywordsSensitivity analysis
    keywordsThermal energy storage
    keywordsTemperature
    keywordsCooling
    keywordsSimulation AND Structures
    treeJournal of Solar Energy Engineering:;2007:;volume( 129 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian