    Study of Internal Finishing of Austenitic Stainless Steel Capillary Tubes by Magnetic Abrasive Finishing

    Source: Journal of Manufacturing Science and Engineering:;2007:;volume( 129 ):;issue: 005::page 885
    Author:
    Hitomi Yamaguchi
    ,
    Takeo Shinmura
    ,
    Ryota Ikeda
    DOI: 10.1115/1.2738957
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper studies the internal finishing of capillary tubes using a magnetic abrasive finishing process. Such tubes are used with nanoscale technologies and meet the demands of the present age in medical and chemical equipment. The finishing characteristics are influenced by the magnetic abrasive behavior against the inner surface of the capillary, which is controlled by the supplied amount of magnetic abrasive and the magnetic force acting on it. The development of the finishing unit identifies the characteristics of the magnetic field, which controls the magnetic force, required for the necessary magnetic abrasive behavior. Finishing experiments using SUS304 austenitic stainless steel capillary tube with 800μm inner diameter demonstrate the effects of the supplied amount of the magnetic abrasive on the finishing characteristics, and the results suggest a standard method to determine the amount to achieve sufficient finishing. The run-out of the capillary while rotating at high speed under the cantilever tube support method causes instability of the magnetic abrasive behavior. The effects on the finishing characteristics are discussed, and a method to diminish the run-out is applied. Accordingly, this paper presents the conditions required for the internal finishing of capillary tubes and proposes methods to realize them. The internal finishing of 400μm inner diameter capillary tubes conveys an understanding of the mechanisms involved and demonstrates the usefulness of the proposed methods.
    keyword(s): Finishing , Magnetic fields , Poles (Building) AND Stainless steel ,
    • Download: (994.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Study of Internal Finishing of Austenitic Stainless Steel Capillary Tubes by Magnetic Abrasive Finishing

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/136254
    Collections
    • Journal of Manufacturing Science and Engineering

    Show full item record

    contributor authorHitomi Yamaguchi
    contributor authorTakeo Shinmura
    contributor authorRyota Ikeda
    date accessioned2017-05-09T00:24:42Z
    date available2017-05-09T00:24:42Z
    date copyrightOctober, 2007
    date issued2007
    identifier issn1087-1357
    identifier otherJMSEFK-28024#885_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/136254
    description abstractThis paper studies the internal finishing of capillary tubes using a magnetic abrasive finishing process. Such tubes are used with nanoscale technologies and meet the demands of the present age in medical and chemical equipment. The finishing characteristics are influenced by the magnetic abrasive behavior against the inner surface of the capillary, which is controlled by the supplied amount of magnetic abrasive and the magnetic force acting on it. The development of the finishing unit identifies the characteristics of the magnetic field, which controls the magnetic force, required for the necessary magnetic abrasive behavior. Finishing experiments using SUS304 austenitic stainless steel capillary tube with 800μm inner diameter demonstrate the effects of the supplied amount of the magnetic abrasive on the finishing characteristics, and the results suggest a standard method to determine the amount to achieve sufficient finishing. The run-out of the capillary while rotating at high speed under the cantilever tube support method causes instability of the magnetic abrasive behavior. The effects on the finishing characteristics are discussed, and a method to diminish the run-out is applied. Accordingly, this paper presents the conditions required for the internal finishing of capillary tubes and proposes methods to realize them. The internal finishing of 400μm inner diameter capillary tubes conveys an understanding of the mechanisms involved and demonstrates the usefulness of the proposed methods.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleStudy of Internal Finishing of Austenitic Stainless Steel Capillary Tubes by Magnetic Abrasive Finishing
    typeJournal Paper
    journal volume129
    journal issue5
    journal titleJournal of Manufacturing Science and Engineering
    identifier doi10.1115/1.2738957
    journal fristpage885
    journal lastpage892
    identifier eissn1528-8935
    keywordsFinishing
    keywordsMagnetic fields
    keywordsPoles (Building) AND Stainless steel
    treeJournal of Manufacturing Science and Engineering:;2007:;volume( 129 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian